Feasibility of automated AI-based contouring and stable radiomic feature assessment by HyperSight-CBCT Imaging for adaptive high-precision radiotherapy of prostate cancer

This study evaluated segmentation accuracy, efficiency, and radiomic feature stability for manual (MD), artificial intelligence-based (AI), and hybrid (MD + AI) contouring of pelvic organs on planning CT (pCT) and HyperSight cone-beam CT (hCBCT) for adaptive radiotherapy. Dice similarity and 95th percentile Hausdorff distance (HD95) quantified segmentation agreement, while radiomic feature stability was assessed using the concordance correlation coefficient (CCC). Agreement between segmentation approaches was highest for bladder and femora (median Dice 0.95–0.96; HD95 1.88–2.17 mm), intermediate for prostate and rectum (median Dice 0.92; HD95 2.22–2.62 mm), and lowest for seminal vesicles and penile bulb (median Dice 0.76–0.83; HD95 3.01–3.41 mm). AI and MD + AI reduced contouring times by about 90% and 60% compared to MD. Radiomic feature stability differed significantly between segmentation modes (all padj ≤ 0.05). GLRLM features exhibited significantly higher stability than other features, whereas morphological features showed lower stability. Median radiomic feature stability was highest for bladder and femora, and intermediate for prostate and rectum. In conclusion, AI-based and hybrid contouring achieved high accuracy and substantial time savings, while texture- and intensity-based radiomic features showed robustness with AI segmentation. This study demonstrated feasibility of extracting distinct, reliable quantitative parameters based on AI-only contouring of pelvic structures.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2026-04-11
DOI
https://doi.org/10.1038/s41598-026-46359-3
Primary Topic
Advanced Radiotherapy Techniques
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Feasibility of automated AI-based contouring and stable radiomic feature assessment by HyperSight-CBCT Imaging for adaptive high-precision radiotherapy of prostate cancer

Frank A. Giordano, Florian Stieler, Victor Siefert, Marvin Willam et al.
Scientific Reports
Advanced Radiotherapy Techniques
article

Feasibility of automated AI-based contouring and stable radiomic feature assessment by HyperSight-CBCT Imaging for adaptive high-precision radiotherapy of prostate cancer

Frank A. Giordano, Florian Stieler, Victor Siefert, Marvin Willam, Michael Ehmann, Constantin Dreher, Miriam Eckl, Daniel Buergy, Ralf Schmidt, Alicia S. Bicu, Judit Boda-Heggemann, Dion Bajerski, Matthias F. Froelich, Jens Fleckenstein, Stefan O. Schoenberg
article en

Abstract

This study evaluated segmentation accuracy, efficiency, and radiomic feature stability for manual (MD), artificial intelligence-based (AI), and hybrid (MD + AI) contouring of pelvic organs on planning CT (pCT) and HyperSight cone-beam CT (hCBCT) for adaptive radiotherapy. Dice similarity and 95th percentile Hausdorff distance (HD95) quantified segmentation agreement, while radiomic feature stability was assessed using the concordance correlation coefficient (CCC). Agreement between segmentation approaches was highest for bladder and femora (median Dice 0.95–0.96; HD95 1.88–2.17 mm), intermediate for prostate and rectum (median Dice 0.92; HD95 2.22–2.62 mm), and lowest for seminal vesicles and penile bulb (median Dice 0.76–0.83; HD95 3.01–3.41 mm). AI and MD + AI reduced contouring times by about 90% and 60% compared to MD. Radiomic feature stability differed significantly between segmentation modes (all padj ≤ 0.05). GLRLM features exhibited significantly higher stability than other features, whereas morphological features showed lower stability. Median radiomic feature stability was highest for bladder and femora, and intermediate for prostate and rectum. In conclusion, AI-based and hybrid contouring achieved high accuracy and substantial time savings, while texture- and intensity-based radiomic features showed robustness with AI segmentation. This study demonstrated feasibility of extracting distinct, reliable quantitative parameters based on AI-only contouring of pelvic structures.

Scientific ReportsVol. 16(1)
Heidelberg University (DE), University Hospital Heidelberg (DE), University Medical Centre Mannheim (DE)
Siemens Healthineers
Openalex Percentile: Top 22%
Advanced Radiotherapy Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.