Resting and Squeeze Anal Pull‐Through Assessments by Fecobionics Demonstrate Weak Anal Sphincters in Patients With Fecal Incontinence

BACKGROUND: Many fecal incontinence (FI) patients have low anal sphincter pressure, which is thought to be a major pathophysiological mechanism. This is assessed either by stationary or pull-through manometry techniques. Fecobionics is a new device for comprehensive assessment of anorectal function. AIM: To evaluate anal pressure profiles during rest and squeeze pull-through maneuvers in FI patients and normal subjects (NS) using Fecobionics and to compare with current technology. METHODS: Patients with FI (Rome IV criteria) and healthy controls were recruited. FI severity was assessed with FISI questionnaire. Anal pull-through maneuvers were performed using Fecobionics and anorectal manometry (ARM) during rest and maximum anal squeeze, and the pull-through pressures were measured and compared. Data were expressed as median and quartiles. Non-parametric statistical testing was done. RESULTS: O)) (p < 0.02). Furthermore, the difference between maximum squeeze and resting pressure differed between groups (p < 0.01). ARM did not show differences between the groups at rest or maximum squeeze (p >>0.2). Strong association was found between the resting and contracted pull-through pressures (r = 0.74, p < 0.001). Similar strong association was found in traumatic, atraumatic, passive, and urge FI subgroups. Data were not influenced by the magnitude of internal or external anal sphincter defects. Bland Altman plots showed agreement between Fecobionics pull-throughs and ARM. CONCLUSIONS: Fecobionics device showed lower squeeze pressures in FI patients compared to NS during anal pull-through procedure and strong associations between these pressures and FI subgroups.

Authors

Institutions

Publication Details

Journal
Neurogastroenterology & Motility
Published
2026-04-01
DOI
https://doi.org/10.1111/nmo.70318
Primary Topic
Pelvic floor disorders treatments
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Resting and Squeeze Anal Pull‐Through Assessments by Fecobionics Demonstrate Weak Anal Sphincters in Patients With Fecal Incontinence

Hans Gregersen, Delaram Asadi, Danielle Long, Yun Yan et al.
Neurogastroenterology & Motility
Pelvic floor disorders treatments
article

Resting and Squeeze Anal Pull‐Through Assessments by Fecobionics Demonstrate Weak Anal Sphincters in Patients With Fecal Incontinence

Hans Gregersen, Delaram Asadi, Danielle Long, Yun Yan, Satish S. Rao, Abeer Aziz, Giuliana Barron Del Solar, Karlo Fidel, Xiaomei Guo
article en

Abstract

BACKGROUND: Many fecal incontinence (FI) patients have low anal sphincter pressure, which is thought to be a major pathophysiological mechanism. This is assessed either by stationary or pull-through manometry techniques. Fecobionics is a new device for comprehensive assessment of anorectal function. AIM: To evaluate anal pressure profiles during rest and squeeze pull-through maneuvers in FI patients and normal subjects (NS) using Fecobionics and to compare with current technology. METHODS: Patients with FI (Rome IV criteria) and healthy controls were recruited. FI severity was assessed with FISI questionnaire. Anal pull-through maneuvers were performed using Fecobionics and anorectal manometry (ARM) during rest and maximum anal squeeze, and the pull-through pressures were measured and compared. Data were expressed as median and quartiles. Non-parametric statistical testing was done. RESULTS: O)) (p < 0.02). Furthermore, the difference between maximum squeeze and resting pressure differed between groups (p < 0.01). ARM did not show differences between the groups at rest or maximum squeeze (p >>0.2). Strong association was found between the resting and contracted pull-through pressures (r = 0.74, p < 0.001). Similar strong association was found in traumatic, atraumatic, passive, and urge FI subgroups. Data were not influenced by the magnitude of internal or external anal sphincter defects. Bland Altman plots showed agreement between Fecobionics pull-throughs and ARM. CONCLUSIONS: Fecobionics device showed lower squeeze pressures in FI patients compared to NS during anal pull-through procedure and strong associations between these pressures and FI subgroups.

Neurogastroenterology & MotilityVol. 38(4)
Augusta University Health (US), California Medical Innovations Institute (US)
National Institutes of Health
Openalex Percentile: Top 32%
Pelvic floor disorders treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.