Machine learning approach to estimation of in vivo measured dose and treatment planning for total body irradiation

This study aims to enhance the conventional Total Body Irradiation (TBI) dose calculation method which relies on manual calculation using tissue maximum ratio, off axis ratio, and scatter factors, by incorporating machine learning (ML) to predict in vivo measured doses and optimize the number of compensators needed, thereby improving the accuracy and efficacy of TBI treatments. A retrospective analysis was performed on patient data between 2018 and 2022, involving 96 patients. The data included demographics, treatment specifics, and in vivo dose measurements. We developed and evaluated various ML models, including Random Forest, XGBoost, LightGBM, and Gradient Boosting Regressor, using 70% of the data for training and 30% for testing. Model performance was assessed using the Mean Absolute Percentage Error (MAPE). The optimization process adjusted compensator numbers based on ML predictions to better align with the prescribed dose. All ML models outperformed the conventional method, with Gradient Boosting Regressor demonstrating the best performance. It achieved an overall MAPE of 2.52% (maximum 2.95% at hip with hand, minimum 2.19% at umbilicus without arm) in predicting measured doses, which is a significant improvement compared to the conventional method’s overall MAPE of 4.01% (maximum 8.69% at head, minimum 2.74% at umbilicus without arm). Furthermore, the optimization process successfully generated treatment plans with a high degree of conformity to the prescribed doses, achieving a MAPE of 1.69% between the optimized and prescribed doses. The head region, which exhibited the largest discrepancy in the conventional method, saw substantial improvement, while the neck region required an increase in compensators to correct underestimation. The machine learning approach successfully improved the accuracy of in vivo dose predictions and compensator optimization, suggesting an enhancement of conventional methods. This advancement holds the potential to deliver more precise and personalized radiation therapy in TBI treatments.

Authors

Institutions

Publication Details

Journal
Radiation Oncology
Published
2026-04-11
DOI
https://doi.org/10.1186/s13014-026-02829-6
Primary Topic
Advanced Radiotherapy Techniques
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Machine learning approach to estimation of in vivo measured dose and treatment planning for total body irradiation

Hyeongmin Jin, Ji Hyun Chang, Seongmoon Jung, Chang Heon Choi et al.
Radiation Oncology
Advanced Radiotherapy Techniques
article

Machine learning approach to estimation of in vivo measured dose and treatment planning for total body irradiation

Hyeongmin Jin, Ji Hyun Chang, Seongmoon Jung, Chang Heon Choi, HyunCheol Kang, S. Lee, SeongHee Kang, Jaeman Son, Jong Min Park, Jung-in Kim, Joo Ho Lee
article en

Abstract

This study aims to enhance the conventional Total Body Irradiation (TBI) dose calculation method which relies on manual calculation using tissue maximum ratio, off axis ratio, and scatter factors, by incorporating machine learning (ML) to predict in vivo measured doses and optimize the number of compensators needed, thereby improving the accuracy and efficacy of TBI treatments. A retrospective analysis was performed on patient data between 2018 and 2022, involving 96 patients. The data included demographics, treatment specifics, and in vivo dose measurements. We developed and evaluated various ML models, including Random Forest, XGBoost, LightGBM, and Gradient Boosting Regressor, using 70% of the data for training and 30% for testing. Model performance was assessed using the Mean Absolute Percentage Error (MAPE). The optimization process adjusted compensator numbers based on ML predictions to better align with the prescribed dose. All ML models outperformed the conventional method, with Gradient Boosting Regressor demonstrating the best performance. It achieved an overall MAPE of 2.52% (maximum 2.95% at hip with hand, minimum 2.19% at umbilicus without arm) in predicting measured doses, which is a significant improvement compared to the conventional method’s overall MAPE of 4.01% (maximum 8.69% at head, minimum 2.74% at umbilicus without arm). Furthermore, the optimization process successfully generated treatment plans with a high degree of conformity to the prescribed doses, achieving a MAPE of 1.69% between the optimized and prescribed doses. The head region, which exhibited the largest discrepancy in the conventional method, saw substantial improvement, while the neck region required an increase in compensators to correct underestimation. The machine learning approach successfully improved the accuracy of in vivo dose predictions and compensator optimization, suggesting an enhancement of conventional methods. This advancement holds the potential to deliver more precise and personalized radiation therapy in TBI treatments.

Radiation Oncology
Seoul National University (KR), Yonsei University (KR), Korea Research Institute of Standards and Science (KR), New Generation University College (ET), Seoul National University Hospital (KR)
National Research Council of Science and Technology
Openalex Percentile: Top 17%
Advanced Radiotherapy Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.