Independent external validation and head-to-head comparison of guideline-recommended CVD risk prediction models

Cardiovascular disease (CVD) prediction models recommended by guidelines are developed using different populations, predictors, and outcome definitions. The implications of this heterogeneity for risk estimation are unclear, and direct comparisons remain limited. Head-to-head comparison of the performance and transportability of three guideline-endorsed CVD risk prediction models, focusing on their sex-specific performance. We evaluated models recommended by the American Heart Association (PREVENT), European Society of Cardiology (SCORE2), and the National Institute for Health and Care Excellence (QRISK3). Risk of bias was assessed using the PROBAST tool. External validation was performed using the UK Biobank (UKBB) in a primary analysis including all participants with complete data for all models, enabling direct comparison, and in a secondary analysis applying each model to participants meeting its original eligibility criteria. Model performance was assessed using Brier scores, Area Under the Receiver Operating Curve (AUC), and calibration across original and alternative outcome definitions, stratified by sex. The PREVENT, SCORE2, and QRISK3 models varied substantially in terms of predictors, populations, and outcome definitions. We used data from 502,157 UKBB participants for the external validation in the primary analysis. Overall predictive performance (discrimination & calibration), as measured by Brier scores, was generally better in females. The AUC (95% CI) ranged from 0.7092 (0.7090-0.7094) to 0.7468 (0.7465-0.7471) for female and 0.6813 (0.6812-0.6814) to 0.6946 (0.6945-0.6946) for male populations. Calibration was suboptimal, particularly for older individuals, with systematic overestimation of risk. The models showed consistent performance when applied to different outcomes. All models were at high risk of bias. Despite heterogeneity in populations, predictors, and outcome definitions, PREVENT, SCORE2, and QRISK3 showed similar performance in the UKBB. Future studies should focus on prospective and standardized definitions and assessment of candidate predictors and outcomes.

Authors

Institutions

Publication Details

Journal
American Journal of Preventive Cardiology
Published
2026-04-01
DOI
https://doi.org/10.1016/j.ajpc.2026.101625
Primary Topic
Acute Myocardial Infarction Research
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Independent external validation and head-to-head comparison of guideline-recommended CVD risk prediction models

Christos Theodoros Nakas, David Herzig, Mary E. Rupp, Lisa M. Koch et al.
American Journal of Preventive Cardiology
Acute Myocardial Infarction Research
article

Independent external validation and head-to-head comparison of guideline-recommended CVD risk prediction models

Christos Theodoros Nakas, David Herzig, Mary E. Rupp, Lisa M. Koch, Jose García-Tirado, Eleftheria Maria Alexandri, Lia Bally, Lum Kastrati, David J. Maron
article en

Abstract

Cardiovascular disease (CVD) prediction models recommended by guidelines are developed using different populations, predictors, and outcome definitions. The implications of this heterogeneity for risk estimation are unclear, and direct comparisons remain limited. Head-to-head comparison of the performance and transportability of three guideline-endorsed CVD risk prediction models, focusing on their sex-specific performance. We evaluated models recommended by the American Heart Association (PREVENT), European Society of Cardiology (SCORE2), and the National Institute for Health and Care Excellence (QRISK3). Risk of bias was assessed using the PROBAST tool. External validation was performed using the UK Biobank (UKBB) in a primary analysis including all participants with complete data for all models, enabling direct comparison, and in a secondary analysis applying each model to participants meeting its original eligibility criteria. Model performance was assessed using Brier scores, Area Under the Receiver Operating Curve (AUC), and calibration across original and alternative outcome definitions, stratified by sex. The PREVENT, SCORE2, and QRISK3 models varied substantially in terms of predictors, populations, and outcome definitions. We used data from 502,157 UKBB participants for the external validation in the primary analysis. Overall predictive performance (discrimination & calibration), as measured by Brier scores, was generally better in females. The AUC (95% CI) ranged from 0.7092 (0.7090-0.7094) to 0.7468 (0.7465-0.7471) for female and 0.6813 (0.6812-0.6814) to 0.6946 (0.6945-0.6946) for male populations. Calibration was suboptimal, particularly for older individuals, with systematic overestimation of risk. The models showed consistent performance when applied to different outcomes. All models were at high risk of bias. Despite heterogeneity in populations, predictors, and outcome definitions, PREVENT, SCORE2, and QRISK3 showed similar performance in the UKBB. Future studies should focus on prospective and standardized definitions and assessment of candidate predictors and outcomes.

American Journal of Preventive Cardiology
University of Bern (CH), University of Thessaly (GR), University Hospital of Bern (CH), Stanford University (US)
University of Bern
Gender equality
Openalex Percentile: Top 18%
Acute Myocardial Infarction Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.