Effect of catheter advancement technique on needle tip motion during peripheral intravenous insertion

BACKGROUND: Failure to successfully place a peripheral venous access device, also known as a peripheral intravenous catheter, impacts patient care, safety, and satisfaction. While factors like catheter size and insertion angle have been well studied, limited research has examined the influence of catheter advancement techniques on needle tip movement, a key determinant of successful placement and patient outcomes. This study measured needle tip movement during the initial advancement of the catheter off of the needle with three different techniques. METHODS: In this prospective, within-subject crossover study at a single academic medical center, 78 clinicians each performed nine 18-gauge catheter advancements in randomized order, three per technique, into a hand phantom using one-handed self-advancement, two-handed self-advancement, and two-person advancement. Six-degree-of-freedom electromagnetic trackers (0.2 mm spatial resolution) captured needle tip kinematics and catheter advancement. Metrics measured were straight-line displacement, path length, maximum excursion, and the axial and radial components of motion for the first 1 cm of catheter advancement off of the needle. RESULTS: = 0.001) and slightly higher displacement (2.15 ± 1.17 mm). Participants perceived the highest ease of use and effectiveness was two-handed self-advancement. CONCLUSIONS: Two-handed self-advancement minimized unintended needle tip motion during initial catheter advancement off of the needle suggesting prioritization in training curricula. Reducing needle tip motion may lower endothelial injury and intravenous catheter advancement failure, supporting the need for clinical technique studies.

Authors

Institutions

Publication Details

Journal
The Journal of Vascular Access
Published
2026-04-11
DOI
https://doi.org/10.1177/11297298261430813
Primary Topic
Central Venous Catheters and Hemodialysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Effect of catheter advancement technique on needle tip motion during peripheral intravenous insertion

Christopher C. Samouce, Nikolaus Gravenstein, Samsun Lampotang, Mayank Kotadia et al.
The Journal of Vascular Access
Central Venous Catheters and Hemodialysis
article

Effect of catheter advancement technique on needle tip motion during peripheral intravenous insertion

Christopher C. Samouce, Nikolaus Gravenstein, Samsun Lampotang, Mayank Kotadia, S Hamad Sagheer, Rachael Ahn, Hannah Kavelak
article en

Abstract

BACKGROUND: Failure to successfully place a peripheral venous access device, also known as a peripheral intravenous catheter, impacts patient care, safety, and satisfaction. While factors like catheter size and insertion angle have been well studied, limited research has examined the influence of catheter advancement techniques on needle tip movement, a key determinant of successful placement and patient outcomes. This study measured needle tip movement during the initial advancement of the catheter off of the needle with three different techniques. METHODS: In this prospective, within-subject crossover study at a single academic medical center, 78 clinicians each performed nine 18-gauge catheter advancements in randomized order, three per technique, into a hand phantom using one-handed self-advancement, two-handed self-advancement, and two-person advancement. Six-degree-of-freedom electromagnetic trackers (0.2 mm spatial resolution) captured needle tip kinematics and catheter advancement. Metrics measured were straight-line displacement, path length, maximum excursion, and the axial and radial components of motion for the first 1 cm of catheter advancement off of the needle. RESULTS: = 0.001) and slightly higher displacement (2.15 ± 1.17 mm). Participants perceived the highest ease of use and effectiveness was two-handed self-advancement. CONCLUSIONS: Two-handed self-advancement minimized unintended needle tip motion during initial catheter advancement off of the needle suggesting prioritization in training curricula. Reducing needle tip motion may lower endothelial injury and intravenous catheter advancement failure, supporting the need for clinical technique studies.

The Journal of Vascular Access
Florida Department of Education (US), University of Florida (US), Simulation Technologies (United States) (US), Florida College (US)
Openalex Percentile: Top 16%
Central Venous Catheters and Hemodialysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.