High dynamic range shortwave infrared imaging of mice with an InGaAs camera

Significance: Although shortwave infrared (SWIR) imaging provides superior tissue penetration and reduced autofluorescence for preclinical applications, quantitative fluorescence analysis is hindered by the limited dynamic range (DR) of InGaAs cameras, forcing a focus on either bright or dim anatomical features. Aim: We develop a high dynamic range (HDR) imaging method specifically adapted for the high-noise characteristics of InGaAs detectors to enable quantitative fluorescence imaging across wide intensity ranges. We demonstrate that one-time camera calibration based on a series of images encompassing the range of radiance intensities enables all subsequent image processing. Approach: We modified classical HDR algorithms with exposure-time-dependent dark current subtraction, preprocessing to exclude saturated and noisy pixels before camera response function recovery, and dynamic weighting range adjustment to account for shrinking intensity ranges at longer exposures. High dynamic range image processing effects on preclinical imaging outcomes were analyzed using indocyanine green and SWIR-emitting PbS/CdS quantum dots in mouse models. Results: studies showed improvements in contrast-to-noise ratios across all anatomical features, with improvements in vascular contrast while maintaining quantitative accuracy. After one-time camera calibrations, this approach enables rapid processing of subsequent datasets. Conclusions: This software-based HDR SWIR imaging approach eliminates exposure parameter optimization and enables comprehensive biodistribution analysis across all anatomical structures from a single acquisition sequence, significantly streamlining preclinical imaging workflows while preserving quantitative accuracy.

Authors

Institutions

Publication Details

Journal
Journal of Biomedical Optics
Published
2026-04-10
DOI
https://doi.org/10.1117/1.jbo.31.5.054704
Primary Topic
Optical Imaging and Spectroscopy Techniques
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

High dynamic range shortwave infrared imaging of mice with an InGaAs camera

Xingjian Zhong, Allison M. Dennis, Mallory A. Moffett, Yidan Sun et al.
Journal of Biomedical Optics
Optical Imaging and Spectroscopy Techniques
article

High dynamic range shortwave infrared imaging of mice with an InGaAs camera

Xingjian Zhong, Allison M. Dennis, Mallory A. Moffett, Yidan Sun, Amish Patel
article en

Abstract

Significance: Although shortwave infrared (SWIR) imaging provides superior tissue penetration and reduced autofluorescence for preclinical applications, quantitative fluorescence analysis is hindered by the limited dynamic range (DR) of InGaAs cameras, forcing a focus on either bright or dim anatomical features. Aim: We develop a high dynamic range (HDR) imaging method specifically adapted for the high-noise characteristics of InGaAs detectors to enable quantitative fluorescence imaging across wide intensity ranges. We demonstrate that one-time camera calibration based on a series of images encompassing the range of radiance intensities enables all subsequent image processing. Approach: We modified classical HDR algorithms with exposure-time-dependent dark current subtraction, preprocessing to exclude saturated and noisy pixels before camera response function recovery, and dynamic weighting range adjustment to account for shrinking intensity ranges at longer exposures. High dynamic range image processing effects on preclinical imaging outcomes were analyzed using indocyanine green and SWIR-emitting PbS/CdS quantum dots in mouse models. Results: studies showed improvements in contrast-to-noise ratios across all anatomical features, with improvements in vascular contrast while maintaining quantitative accuracy. After one-time camera calibrations, this approach enables rapid processing of subsequent datasets. Conclusions: This software-based HDR SWIR imaging approach eliminates exposure parameter optimization and enables comprehensive biodistribution analysis across all anatomical structures from a single acquisition sequence, significantly streamlining preclinical imaging workflows while preserving quantitative accuracy.

Journal of Biomedical OpticsVol. 31(05)
Boston University (US), Northeastern University (US)
National Institutes of Health, National Institute of General Medical Sciences, National Institute of Biomedical Imaging and Bioengineering
Openalex Percentile: Top 19%
Optical Imaging and Spectroscopy Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.