Hybrid CNN-decision tree framework for efficient transmission line fault detection and classification: an XAI-based approach

Accurate, fast, and interpretable fault identification on electrical transmission lines is essential for maintaining power system stability and reducing outage durations. In this study, we propose a hybrid 1D convolutional neural network-Decision Tree (1D-CNN-DT) for transmission line fault detection and classification, in which the 1D-CNN acts solely as a feature extractor. During this process, the Decision Tree performs the final, interpretable classification. By preserving decision transparency and achieving high diagnostic accuracy, the proposed architecture differs from conventional end-to-end deep learning models. In MATLAB/Simulink, four distinct transmission line scenarios were simulated to evaluate the framework under realistic operating conditions. These scenarios included short lines, long distributed lines, source-end faults, and load-end faults. We developed a large, balanced dataset of three-phase voltage and current measurements per unit, covering standard operation and ten types of faults. According to the proposed model, fault detection accuracies were 99.89%, 99.94%, 99.94%, and 99.97%, and fault classification accuracies were 99.93%, 99.58%, 99.44%, and 99.86% across the four transmission line configurations. In addition to its high accuracy, the hybrid framework demonstrated significantly lower computational complexity and shorter training and inference times than conventional ANN- and LSTM-based approaches, without requiring manual signal transformations. The SHapley Additive Explanations (SHAP) are integrated to enhance trust and practical usability, providing both global and instance-level interpretability that reveals how voltages and currents contribute to individual faults. According to the results, a hybrid architecture that combines deep learning and explainable AI offers reliable, efficient, and transparent real-time transmission line monitoring and protection.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2026-04-10
DOI
https://doi.org/10.1038/s41598-026-45514-0
Primary Topic
Power Systems Fault Detection
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Hybrid CNN-decision tree framework for efficient transmission line fault detection and classification: an XAI-based approach

Rajeswaran Nagalingam, Fariya Bintay Shafi, Anish Kumar Biswas, Md. Faysal Ahamed et al.
Scientific Reports
Power Systems Fault Detection
article

Hybrid CNN-decision tree framework for efficient transmission line fault detection and classification: an XAI-based approach

Rajeswaran Nagalingam, Fariya Bintay Shafi, Anish Kumar Biswas, Md. Faysal Ahamed, Muhammad E. H. Chowdhury, M. Murugappan, T. Samraj Lawrence
article en

Abstract

Accurate, fast, and interpretable fault identification on electrical transmission lines is essential for maintaining power system stability and reducing outage durations. In this study, we propose a hybrid 1D convolutional neural network-Decision Tree (1D-CNN-DT) for transmission line fault detection and classification, in which the 1D-CNN acts solely as a feature extractor. During this process, the Decision Tree performs the final, interpretable classification. By preserving decision transparency and achieving high diagnostic accuracy, the proposed architecture differs from conventional end-to-end deep learning models. In MATLAB/Simulink, four distinct transmission line scenarios were simulated to evaluate the framework under realistic operating conditions. These scenarios included short lines, long distributed lines, source-end faults, and load-end faults. We developed a large, balanced dataset of three-phase voltage and current measurements per unit, covering standard operation and ten types of faults. According to the proposed model, fault detection accuracies were 99.89%, 99.94%, 99.94%, and 99.97%, and fault classification accuracies were 99.93%, 99.58%, 99.44%, and 99.86% across the four transmission line configurations. In addition to its high accuracy, the hybrid framework demonstrated significantly lower computational complexity and shorter training and inference times than conventional ANN- and LSTM-based approaches, without requiring manual signal transformations. The SHapley Additive Explanations (SHAP) are integrated to enhance trust and practical usability, providing both global and instance-level interpretability that reveals how voltages and currents contribute to individual faults. According to the results, a hybrid architecture that combines deep learning and explainable AI offers reliable, efficient, and transparent real-time transmission line monitoring and protection.

Scientific Reports
Vels University (IN), Rajshahi University of Engineering and Technology (BD), IMS Unison University (IN), Samara University (ET), Kuwait College of Science and Technology (KW), MNR Medical College and Hospital (IN), Qatar University (QA)
Openalex Percentile: Top 5%
Power Systems Fault Detection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.