Longitudinal evaluation of HIV-1 LAg incidence assay and proficiency panel stability for external quality assurance

Accurate HIV incidence estimates are essential for monitoring epidemic trends and evaluating prevention efforts. The limiting antigen (LAg) avidity enzyme immunoassay is the most widely used method to classify recent versus long-term HIV infections. The External Quality Assurance Oversight Laboratory (EQAPOL), in collaboration with Vitalant Research Institute, conducts a global External Quality Assurance (EQA) program to evaluate laboratory performance using commercial LAg kits. We assessed (i) the stability of calibrators and reagents from Sedia and Maxim kits over their shelf life, and (ii) the longitudinal consistency of EQA panel samples tested across nine proficiency rounds (2018-2023). Mixed-effects models were used to detect trends in optical density (OD) and normalized OD (ODn) values over time. No significant trends in OD or ODn were observed for either kit, and EQA panel samples showed stable reactivity across all rounds. Minor ODn shifts did not affect recency classification. Sedia kits consistently yielded slightly higher ODn values than Maxim kits, consistent with prior reports. These findings confirm the long-term reliability of both LAg assay kits and EQA panel materials, supporting the robustness of EQAPOL's quality assurance framework for accurate global HIV incidence surveillance.IMPORTANCEReliable estimation of HIV incidence depends on accurate classification of recent versus long-term infections, which in turn requires consistent assay performance and robust quality assurance. The External Quality Assurance Oversight Laboratory LAg External Quality Assurance program provides longitudinal monitoring of laboratory proficiency for two widely used commercial assays. By demonstrating the long-term consistency of calibrators, reagents, and quality control panels across multiple production lots and testing rounds, this study confirms the robustness of the global limiting antigen testing framework. These results strengthen confidence in the comparability of HIV incidence data across surveillance networks and geographic regions, supporting evidence-based decision-making for HIV prevention programs.

Authors

Institutions

Publication Details

Journal
Microbiology Spectrum
Published
2026-04-10
DOI
https://doi.org/10.1128/spectrum.03584-25
Primary Topic
HIV Research and Treatment
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Longitudinal evaluation of HIV-1 LAg incidence assay and proficiency panel stability for external quality assurance

Jahnavi Reddy Bhaskar, Cassandra G. Porth, Eduard Grebe, Wes Rountree et al.
Microbiology Spectrum
HIV Research and Treatment
article

Longitudinal evaluation of HIV-1 LAg incidence assay and proficiency panel stability for external quality assurance

Jahnavi Reddy Bhaskar, Cassandra G. Porth, Eduard Grebe, Wes Rountree, Michael Paul Busch, Clara Di Germanio, Aditi Sanghavi, Brendan G. Balasko, Paul M. Hargarten, Marek S. Poniewierski, Mars Stone, Patricia G. Villaflor, Thomas N. Denny, Sylvester Hood
article en

Abstract

Accurate HIV incidence estimates are essential for monitoring epidemic trends and evaluating prevention efforts. The limiting antigen (LAg) avidity enzyme immunoassay is the most widely used method to classify recent versus long-term HIV infections. The External Quality Assurance Oversight Laboratory (EQAPOL), in collaboration with Vitalant Research Institute, conducts a global External Quality Assurance (EQA) program to evaluate laboratory performance using commercial LAg kits. We assessed (i) the stability of calibrators and reagents from Sedia and Maxim kits over their shelf life, and (ii) the longitudinal consistency of EQA panel samples tested across nine proficiency rounds (2018-2023). Mixed-effects models were used to detect trends in optical density (OD) and normalized OD (ODn) values over time. No significant trends in OD or ODn were observed for either kit, and EQA panel samples showed stable reactivity across all rounds. Minor ODn shifts did not affect recency classification. Sedia kits consistently yielded slightly higher ODn values than Maxim kits, consistent with prior reports. These findings confirm the long-term reliability of both LAg assay kits and EQA panel materials, supporting the robustness of EQAPOL's quality assurance framework for accurate global HIV incidence surveillance.IMPORTANCEReliable estimation of HIV incidence depends on accurate classification of recent versus long-term infections, which in turn requires consistent assay performance and robust quality assurance. The External Quality Assurance Oversight Laboratory LAg External Quality Assurance program provides longitudinal monitoring of laboratory proficiency for two widely used commercial assays. By demonstrating the long-term consistency of calibrators, reagents, and quality control panels across multiple production lots and testing rounds, this study confirms the robustness of the global limiting antigen testing framework. These results strengthen confidence in the comparability of HIV incidence data across surveillance networks and geographic regions, supporting evidence-based decision-making for HIV prevention programs.

Microbiology SpectrumVol. 14(5)
International Vaccine Institute (KR), Duke University (US), Vitalant (US)
Good health and well-being
Openalex Percentile: Top 25%
HIV Research and Treatment
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.