Matching the protocol to the clinical question in pediatric coronary CT - one size doesn't have to fit all

PURPOSE: To compare image quality and radiation dose between pediatric coronary CT protocols. METHODS: A retrospective observational study of pediatric coronary CT in children under 2 years old undergoing awake, non-sedated imaging in a pediatric cardiac surgical centre, comparing non-gated high-pitch dual source spiral (ng-FLASH); ECG-gated FLASH (FLASH); single-phase (30 ​% R-R) and multiphase (30-50 ​% R-R) sequential acquisition protocols. Dose metrics (DLP and CTDIvol) were collected and coronary visualisation assessed for the left mainstem (0 ​= ​not visible; 1 ​= ​visible), anterior descending, circumflex and right coronary arteries (0 ​= ​not visible; 1 ​= ​origin only; 2 ​= ​to mid-vessel; 3 ​= ​whole vessel). RESULTS: 128 consecutive studies were identified (84 ​ng-FLASH, 23 FLASH, 7 single-phase and 14 multi-phase sequential); median age was 3 months (range 1 day-17 months). Multi-phase sequential scans were the highest dose (median CTDI vol 1.66 ​mGy); cf. single-phase sequential 1.20 ​mGy (p ​= ​1.00); FLASH 0.57 ​mGy (p ​< ​0.001) and ng-FLASH 0.45 ​mGy (p ​< ​0.001). Multi-phase sequential scans had best image quality (median score 8, IQR 1.75) cf. single-phase sequential scans; 6, 5, p ​= ​0.95; FLASH 5, 5, p ​= ​0.15, and ng-FLASH 4, 3, p ​= ​0.001). Multi-phase acquisitions visualised coronaries to at least the mid-portion in 71.4 ​% (vs. 28.6 ​% single-phase sequential, 30.4 ​% FLASH and 13.1 ​% ng-FLASH). CONCLUSIONS: Coronary visualisation via CT in under-2 year olds can be achieved at a fraction of the dose expected from retrospective ECG gating, without anaesthesia. Where full coronary visualisation is not the primary aim of the examination, scan protocol can be adjusted accordingly. Stepwise increases in radiation exposure can be added according to level of coronary assessment required.

Authors

Institutions

Publication Details

Journal
Journal of cardiovascular computed tomography
Published
2026-04-01
DOI
https://doi.org/10.1016/j.jcct.2026.02.004
Primary Topic
Cardiac Imaging and Diagnostics
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Matching the protocol to the clinical question in pediatric coronary CT - one size doesn't have to fit all

Edward David Nicol, Thomas R. Semple, Emily Ashworth, I. Castellano et al.
Journal of cardiovascular computed tomography
Cardiac Imaging and Diagnostics
article

Matching the protocol to the clinical question in pediatric coronary CT - one size doesn't have to fit all

Edward David Nicol, Thomas R. Semple, Emily Ashworth, I. Castellano, S. Padley, E. McDonagh, F. Sheikh, M. Rubens, V. Cuculovic
article en

Abstract

PURPOSE: To compare image quality and radiation dose between pediatric coronary CT protocols. METHODS: A retrospective observational study of pediatric coronary CT in children under 2 years old undergoing awake, non-sedated imaging in a pediatric cardiac surgical centre, comparing non-gated high-pitch dual source spiral (ng-FLASH); ECG-gated FLASH (FLASH); single-phase (30 ​% R-R) and multiphase (30-50 ​% R-R) sequential acquisition protocols. Dose metrics (DLP and CTDIvol) were collected and coronary visualisation assessed for the left mainstem (0 ​= ​not visible; 1 ​= ​visible), anterior descending, circumflex and right coronary arteries (0 ​= ​not visible; 1 ​= ​origin only; 2 ​= ​to mid-vessel; 3 ​= ​whole vessel). RESULTS: 128 consecutive studies were identified (84 ​ng-FLASH, 23 FLASH, 7 single-phase and 14 multi-phase sequential); median age was 3 months (range 1 day-17 months). Multi-phase sequential scans were the highest dose (median CTDI vol 1.66 ​mGy); cf. single-phase sequential 1.20 ​mGy (p ​= ​1.00); FLASH 0.57 ​mGy (p ​< ​0.001) and ng-FLASH 0.45 ​mGy (p ​< ​0.001). Multi-phase sequential scans had best image quality (median score 8, IQR 1.75) cf. single-phase sequential scans; 6, 5, p ​= ​0.95; FLASH 5, 5, p ​= ​0.15, and ng-FLASH 4, 3, p ​= ​0.001). Multi-phase acquisitions visualised coronaries to at least the mid-portion in 71.4 ​% (vs. 28.6 ​% single-phase sequential, 30.4 ​% FLASH and 13.1 ​% ng-FLASH). CONCLUSIONS: Coronary visualisation via CT in under-2 year olds can be achieved at a fraction of the dose expected from retrospective ECG gating, without anaesthesia. Where full coronary visualisation is not the primary aim of the examination, scan protocol can be adjusted accordingly. Stepwise increases in radiation exposure can be added according to level of coronary assessment required.

Journal of cardiovascular computed tomography
Royal Brompton Hospital (GB), NIHR Royal Brompton Cardiovascular Biomedical Research Unit (GB), Royal Marsden Hospital (GB), Imperial College London (GB)
National Institute for Health and Care Research
Openalex Percentile: Top 18%
Cardiac Imaging and Diagnostics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.