Feasibility and agreement of a self-adhesive EEG electrode set versus conventional EEG in postanoxic coma

BACKGROUND: Electrode application for EEG prognostication in postanoxic coma patients is labor-intensive. We studied the usability of a self-adhesive forehead EEG electrode (Bittium BrainStatus™) and compared the accuracy of background classification with conventional EEG. METHODS: In 51 postanoxic coma patients, simultaneous monitoring using conventional EEG and a forehead electrode was performed. 5-min EEG fragments were classified according to the ACNS criteria by four experts, based on the conventional montage, the forehead electrode, and a montage based on the standard EEG recording but visualized as the forehead electrode. RESULTS: Forehead electrode recordings were of sufficient quality in 74.1% of fragments. Agreement was moderate for standard EEG versus the forehead electrode (κ: 0.56), and near perfect for conventional EEG versus conventional EEG visualized as the forehead electrode (κ: 0.85). Due to higher noise levels, detection rates of discontinuous and suppressed patterns were reduced. CONCLUSION: EEG forehead electrode recordings were interpretable in a large proportion of cases. If signal quality is insufficient for assessment, additional standard EEG should be performed to allow definitive assessment. SIGNIFICANCE: The use of a self-adhesive forehead electrode set has the potential to substantially reduce EEG technician workload in the ICU and suggests considerable potential benefit as a screening-oriented EEG monitoring strategy in postanoxic coma.

Authors

Institutions

Publication Details

Journal
Resuscitation
Published
2026-04-10
DOI
https://doi.org/10.1016/j.resuscitation.2026.111086
Primary Topic
Anesthesia and Sedative Agents
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Feasibility and agreement of a self-adhesive EEG electrode set versus conventional EEG in postanoxic coma

Robert van den Berg, Maartje Louter, Judith Drenthen, Mark van de Ruit et al.
Resuscitation
Anesthesia and Sedative Agents
article

Feasibility and agreement of a self-adhesive EEG electrode set versus conventional EEG in postanoxic coma

Robert van den Berg, Maartje Louter, Judith Drenthen, Mark van de Ruit, Marit Verboom, Dirk C.G. Straver, Mathieu van der Jagt
article en

Abstract

BACKGROUND: Electrode application for EEG prognostication in postanoxic coma patients is labor-intensive. We studied the usability of a self-adhesive forehead EEG electrode (Bittium BrainStatus™) and compared the accuracy of background classification with conventional EEG. METHODS: In 51 postanoxic coma patients, simultaneous monitoring using conventional EEG and a forehead electrode was performed. 5-min EEG fragments were classified according to the ACNS criteria by four experts, based on the conventional montage, the forehead electrode, and a montage based on the standard EEG recording but visualized as the forehead electrode. RESULTS: Forehead electrode recordings were of sufficient quality in 74.1% of fragments. Agreement was moderate for standard EEG versus the forehead electrode (κ: 0.56), and near perfect for conventional EEG versus conventional EEG visualized as the forehead electrode (κ: 0.85). Due to higher noise levels, detection rates of discontinuous and suppressed patterns were reduced. CONCLUSION: EEG forehead electrode recordings were interpretable in a large proportion of cases. If signal quality is insufficient for assessment, additional standard EEG should be performed to allow definitive assessment. SIGNIFICANCE: The use of a self-adhesive forehead electrode set has the potential to substantially reduce EEG technician workload in the ICU and suggests considerable potential benefit as a screening-oriented EEG monitoring strategy in postanoxic coma.

ResuscitationVol. 223
Erasmus MC (NL), Erasmus University Rotterdam (NL), Delft University of Technology (NL)
Erasmus Medisch Centrum
Openalex Percentile: Top 21%
Anesthesia and Sedative Agents
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.