Methodological approach for calibration transfer from benchtop to portable SWIR spectrometers: a laboratory-scale study on powdered grapevine leaves

Near- and short-wave infrared spectroscopy has become increasingly relevant for the assessment of plant composition, yet the reproducibility of chemometric models across different instruments remains a major limitation. This work proposes a methodological approach for calibration transfer from a benchtop hyperspectral imaging (HSI) system to a portable SWIR spectrometer, using powdered grapevine leaves as a controlled case study. The strategy relies on Direct Standardization (DS), a technique that transforms spectra acquired under different conditions into a common space. By applying DS to a representative subset of samples, models trained under laboratory conditions can be adapted to spectra acquired with portable devices. Two complementary modelling strategies were adopted: an Error-Correcting Output Codes Support Vector Machine (ECOC-SVM) classifier, used to assess qualitative improvements in class discrimination before and after DS, and an eXtreme Gradient Boosting (XGB) regression model, developed for quantitative prediction of elemental concentrations measured by micro-XRF. Validation on an independent set of homogenized leaf powders confirmed that DS markedly reduced inter-instrument spectral divergence, improving class separability and enabling accurate regression of macro- and micronutrients (Fe, Mn, P, S, Zn, Ca, K, Si). Although limited to laboratory-scale samples, the study demonstrates that calibration transfer is effective in harmonizing spectral domains. The proposed workflow provides a reproducible and scalable methodology for cross-instrument adaptation, with potential applicability to diverse agricultural products and portable spectroscopy platforms.

Authors

Institutions

Publication Details

Journal
Spectrochimica Acta Part A Molecular and Biomolecular Spectroscopy
Published
2026-04-10
DOI
https://doi.org/10.1016/j.saa.2026.127866
Primary Topic
Spectroscopy and Chemometric Analyses
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Methodological approach for calibration transfer from benchtop to portable SWIR spectrometers: a laboratory-scale study on powdered grapevine leaves

Giuseppe Capobianco, Gabriella Tamasi, Claudio Rossi, Silvia Serranti et al.
Spectrochimica Acta Part A Molecular and Biomolecular Spectroscopy
Spectroscopy and Chemometric Analyses
article

Methodological approach for calibration transfer from benchtop to portable SWIR spectrometers: a laboratory-scale study on powdered grapevine leaves

Giuseppe Capobianco, Gabriella Tamasi, Claudio Rossi, Silvia Serranti, Giuseppe Bonifazi
article en

Abstract

Near- and short-wave infrared spectroscopy has become increasingly relevant for the assessment of plant composition, yet the reproducibility of chemometric models across different instruments remains a major limitation. This work proposes a methodological approach for calibration transfer from a benchtop hyperspectral imaging (HSI) system to a portable SWIR spectrometer, using powdered grapevine leaves as a controlled case study. The strategy relies on Direct Standardization (DS), a technique that transforms spectra acquired under different conditions into a common space. By applying DS to a representative subset of samples, models trained under laboratory conditions can be adapted to spectra acquired with portable devices. Two complementary modelling strategies were adopted: an Error-Correcting Output Codes Support Vector Machine (ECOC-SVM) classifier, used to assess qualitative improvements in class discrimination before and after DS, and an eXtreme Gradient Boosting (XGB) regression model, developed for quantitative prediction of elemental concentrations measured by micro-XRF. Validation on an independent set of homogenized leaf powders confirmed that DS markedly reduced inter-instrument spectral divergence, improving class separability and enabling accurate regression of macro- and micronutrients (Fe, Mn, P, S, Zn, Ca, K, Si). Although limited to laboratory-scale samples, the study demonstrates that calibration transfer is effective in harmonizing spectral domains. The proposed workflow provides a reproducible and scalable methodology for cross-instrument adaptation, with potential applicability to diverse agricultural products and portable spectroscopy platforms.

Spectrochimica Acta Part A Molecular and Biomolecular SpectroscopyVol. 358
University of Siena (IT), Sapienza University of Rome (IT)
European Commission
Zero hunger
Openalex Percentile: Top 32%
Spectroscopy and Chemometric Analyses
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.