Finite element analysis of titanium cable tensioning ring fixation in the treatment of distal tibiofibular syndesmosis injury

This study employs the finite element analysis method to compare the biomechanical differences between 2 different internal fixation techniques: the novel surgical approach of using titanium cable tensioning ring for distal tibiofibular syndesmosis (DTS) injuries and the conventional method of utilizing Endobutton plate. Utilizing a CT image of the ankle joint from a healthy adult, models representing a normal ankle joint (Model A), a DTS injury (Model B), a titanium cable tensioning ring (Model C), and an endobutton plate fixation (Model D) were developed through finite element software. The Von Mises stress and fibula displacement relative to the tibia were assessed in each model across 3 loading conditions: standing on 1 leg, ankle internal rotation, and ankle external rotation. Across 3 loading conditions, Model B exhibited the greatest displacement of the fibula compared to Model A, with a maximum rate of increase of 166.3% for anterior and posterior displacement, and 265.7% for internal and external displacement. The fibula displacement rates relative to the tibia in Models C and D were below 20%. Additionally, Model B showed the highest maximum stress on the tibiotalar joint surface, increasing by 42.1%, 41.2%, and 35.0% when standing on 1 foot, pronating inward, and pronating outward, respectively. Conversely, the increase in maximum stress on the tibiotalar joint surface in Models C and D was <5%, resulting in a significant reduction of stress on the tibiotalar joint surface following DTS injury. The results showed that high efficacy in treating DTS injuries was demonstrated by the titanium cable tensioning ring, comparable to the effectiveness of an endobutton plate.

Authors

Institutions

Publication Details

Journal
Medicine
Published
2026-04-10
DOI
https://doi.org/10.1097/md.0000000000048208
Primary Topic
Foot and Ankle Surgery
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Finite element analysis of titanium cable tensioning ring fixation in the treatment of distal tibiofibular syndesmosis injury

Zuoming Yang, J. Sun, Pengfei Guan, Bin Wang et al.
Medicine
Foot and Ankle Surgery
article

Finite element analysis of titanium cable tensioning ring fixation in the treatment of distal tibiofibular syndesmosis injury

Zuoming Yang, J. Sun, Pengfei Guan, Bin Wang, Xiaoming Zhao
article en

Abstract

This study employs the finite element analysis method to compare the biomechanical differences between 2 different internal fixation techniques: the novel surgical approach of using titanium cable tensioning ring for distal tibiofibular syndesmosis (DTS) injuries and the conventional method of utilizing Endobutton plate. Utilizing a CT image of the ankle joint from a healthy adult, models representing a normal ankle joint (Model A), a DTS injury (Model B), a titanium cable tensioning ring (Model C), and an endobutton plate fixation (Model D) were developed through finite element software. The Von Mises stress and fibula displacement relative to the tibia were assessed in each model across 3 loading conditions: standing on 1 leg, ankle internal rotation, and ankle external rotation. Across 3 loading conditions, Model B exhibited the greatest displacement of the fibula compared to Model A, with a maximum rate of increase of 166.3% for anterior and posterior displacement, and 265.7% for internal and external displacement. The fibula displacement rates relative to the tibia in Models C and D were below 20%. Additionally, Model B showed the highest maximum stress on the tibiotalar joint surface, increasing by 42.1%, 41.2%, and 35.0% when standing on 1 foot, pronating inward, and pronating outward, respectively. Conversely, the increase in maximum stress on the tibiotalar joint surface in Models C and D was <5%, resulting in a significant reduction of stress on the tibiotalar joint surface following DTS injury. The results showed that high efficacy in treating DTS injuries was demonstrated by the titanium cable tensioning ring, comparable to the effectiveness of an endobutton plate.

MedicineVol. 105(15)
Cangzhou Central Hospital (CN), Second Hospital of Tangshan (CN)
Good health and well-being
Openalex Percentile: Top 16%
Foot and Ankle Surgery
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Finite element analysis of titanium cable tensioning ring fixation in the treatment of distal tibiofibular syndesmosis injury — Zuoming Yang, J. Sun, et al. · Medicine (2026) | TGRS Research Map | TGRS