Fuzzy Logic‐Based Load Analysis of Hybrid Microgrid System Including Fuel Cell, Wind Turbine, Wave, and Photovoltaic Energies

ABSTRACT The effective use of renewable energy sources (RES) and advanced energy management strategies ensures an environmentally friendly and cost‐effective energy supply. The study presented investigates the performance of a hybrid microgrid system (HMGS) designed to meet the energy demand of the Ildır Bay region in İzmir, Türkiye, representing a remote coastal community. The system operates in island mode, integrating wave energy into a configuration that already includes continuous energy sources, such as a fuel cell, to exploit the potential of suitable locations without compromising stability. The HMGS consists of four main energy sources: a 50 kW DC fuel cell (FC) stack, a 100 kW photovoltaic (PV) system, a 30 kW wind energy (WE) unit, and a 20 kW oscillating water column (OWC) wave energy (WvE) system, totaling 200 kW. MATLAB/Simulink is used for system modeling, and a fuzzy‐logic (FL)‐based load management (LM) system, combined with a Smart FC Dispatch strategy, is proposed to minimize energy waste and enhance operational flexibility. A 24 h simulation is performed to evaluate system performance under different load conditions. Simulation results show that without LM, the simultaneous demand of 150 kW leads to rapid battery depletion and potential system blackout. In contrast, the proposed strategy dynamically sheds noncritical loads and regulates FC output based on the battery state of charge (SOC). This approach ensures a continuous supply for the 20 kW critical load, maintains the battery SOC above 80%, and reduces unnecessary hydrogen consumption by preventing excessive FC operation. Furthermore, harmonic analysis confirms that the system complies with IEEE‐519 power quality standards. Overall, the proposed HMGS offers an innovative and sustainable solution to meet the continuous energy needs of modern coastal communities.

Authors

Institutions

Publication Details

Journal
Fuel Cells
Published
2026-04-01
DOI
https://doi.org/10.1002/fuce.70093
Primary Topic
Hybrid Renewable Energy Systems
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Fuzzy Logic‐Based Load Analysis of Hybrid Microgrid System Including Fuel Cell, Wind Turbine, Wave, and Photovoltaic Energies

Şule ATAÇ, Mehmet Güçyetmez
Fuel Cells
Hybrid Renewable Energy Systems
article

Fuzzy Logic‐Based Load Analysis of Hybrid Microgrid System Including Fuel Cell, Wind Turbine, Wave, and Photovoltaic Energies

Şule ATAÇ, Mehmet Güçyetmez
article en

Abstract

ABSTRACT The effective use of renewable energy sources (RES) and advanced energy management strategies ensures an environmentally friendly and cost‐effective energy supply. The study presented investigates the performance of a hybrid microgrid system (HMGS) designed to meet the energy demand of the Ildır Bay region in İzmir, Türkiye, representing a remote coastal community. The system operates in island mode, integrating wave energy into a configuration that already includes continuous energy sources, such as a fuel cell, to exploit the potential of suitable locations without compromising stability. The HMGS consists of four main energy sources: a 50 kW DC fuel cell (FC) stack, a 100 kW photovoltaic (PV) system, a 30 kW wind energy (WE) unit, and a 20 kW oscillating water column (OWC) wave energy (WvE) system, totaling 200 kW. MATLAB/Simulink is used for system modeling, and a fuzzy‐logic (FL)‐based load management (LM) system, combined with a Smart FC Dispatch strategy, is proposed to minimize energy waste and enhance operational flexibility. A 24 h simulation is performed to evaluate system performance under different load conditions. Simulation results show that without LM, the simultaneous demand of 150 kW leads to rapid battery depletion and potential system blackout. In contrast, the proposed strategy dynamically sheds noncritical loads and regulates FC output based on the battery state of charge (SOC). This approach ensures a continuous supply for the 20 kW critical load, maintains the battery SOC above 80%, and reduces unnecessary hydrogen consumption by preventing excessive FC operation. Furthermore, harmonic analysis confirms that the system complies with IEEE‐519 power quality standards. Overall, the proposed HMGS offers an innovative and sustainable solution to meet the continuous energy needs of modern coastal communities.

Fuel CellsVol. 26(2)
Sivas State Hospital (TR), Sivas Bilim ve Teknoloji Üniversitesi (TR)
Openalex Percentile: Top 23%
Hybrid Renewable Energy Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.