Influence of ocular biometry on peripheral retinal visualization: a comparative study of Clarus and Optos widefield imaging systems

BACKGROUND: The purpose was to compare the Clarus 500 and Optos Daytona widefield imaging systems with respect to the farthest clinically assessable peripheral retinal structure in each quadrant, and to evaluate whether ocular biometry, particularly axial length and spherical equivalent, influences device specific widefield performance. METHODS: Twenty-six eyes underwent same day widefield imaging with Clarus 500 (Zeiss Meditec AG, Jena, Germany) and Optos Daytona (Optos plc, Dunfermline, UK). For each quadrant, the most peripheral anatomically interpretable structure was identified, and device differences were analyzed using McNemar tests. Associations with axial length and spherical equivalent, were evaluated using Mann-Whitney U tests and univariate and multivariate logistic regression. Receiver operating characteristic analysis was performed to assess the predictive value of axial length and to determine the optimal cutoff for device superiority. RESULTS: Both widefield systems showed similar performance in the superior temporal, inferior temporal, and inferior nasal quadrants with no statistically significant differences. In the superior nasal quadrant, however, eyes in which Clarus reached farther had significantly longer axial length (23.97 ± 1.62 mm versus 22.53 ± 0.94 mm, p = 0.016) and a more myopic spherical equivalent (- 2.05 ± 4.52 D versus + 2.69 ± 2.56 D, p = 0.019). Axial length significantly predicted cases in which Clarus reached farther into the periphery in univariate regression (odds ratio 2.39, p = 0.033). Receiver operating characteristic analysis demonstrated good discriminatory ability of axial length with an area under the curve of 0.782 and an optimal cutoff of 23.77 mm. Shorter and hyperopic eyes showed a tendency toward greater peripheral reach with Optos, although this trend did not achieve statistical significance. CONCLUSION: An axial length cutoff value of 23.77 mm was identified as a threshold for device-specific differences in peripheral retinal visualization. Device differences become apparent in the superior nasal quadrant, where axial elongation and myopic ocular geometry were associated with greater peripheral reach of the Clarus system, while no statistically supported advantage for Optos is observed in shorter or hyperopic eyes. Overall, the Clarus 500 and Optos Daytona provide comparable peripheral visualization in most retinal quadrants. These findings should be interpreted in the context of the exploratory study design.

Authors

Institutions

Publication Details

Journal
BMC Ophthalmology
Published
2026-04-11
DOI
https://doi.org/10.1186/s12886-026-04782-0
Primary Topic
Retinal and Macular Surgery
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Influence of ocular biometry on peripheral retinal visualization: a comparative study of Clarus and Optos widefield imaging systems

Andreea Fișus, Christoph Spartalis, Manuel Ruiss, Oliver Findl
BMC Ophthalmology
Retinal and Macular Surgery
article

Influence of ocular biometry on peripheral retinal visualization: a comparative study of Clarus and Optos widefield imaging systems

Andreea Fișus, Christoph Spartalis, Manuel Ruiss, Oliver Findl
article en

Abstract

BACKGROUND: The purpose was to compare the Clarus 500 and Optos Daytona widefield imaging systems with respect to the farthest clinically assessable peripheral retinal structure in each quadrant, and to evaluate whether ocular biometry, particularly axial length and spherical equivalent, influences device specific widefield performance. METHODS: Twenty-six eyes underwent same day widefield imaging with Clarus 500 (Zeiss Meditec AG, Jena, Germany) and Optos Daytona (Optos plc, Dunfermline, UK). For each quadrant, the most peripheral anatomically interpretable structure was identified, and device differences were analyzed using McNemar tests. Associations with axial length and spherical equivalent, were evaluated using Mann-Whitney U tests and univariate and multivariate logistic regression. Receiver operating characteristic analysis was performed to assess the predictive value of axial length and to determine the optimal cutoff for device superiority. RESULTS: Both widefield systems showed similar performance in the superior temporal, inferior temporal, and inferior nasal quadrants with no statistically significant differences. In the superior nasal quadrant, however, eyes in which Clarus reached farther had significantly longer axial length (23.97 ± 1.62 mm versus 22.53 ± 0.94 mm, p = 0.016) and a more myopic spherical equivalent (- 2.05 ± 4.52 D versus + 2.69 ± 2.56 D, p = 0.019). Axial length significantly predicted cases in which Clarus reached farther into the periphery in univariate regression (odds ratio 2.39, p = 0.033). Receiver operating characteristic analysis demonstrated good discriminatory ability of axial length with an area under the curve of 0.782 and an optimal cutoff of 23.77 mm. Shorter and hyperopic eyes showed a tendency toward greater peripheral reach with Optos, although this trend did not achieve statistical significance. CONCLUSION: An axial length cutoff value of 23.77 mm was identified as a threshold for device-specific differences in peripheral retinal visualization. Device differences become apparent in the superior nasal quadrant, where axial elongation and myopic ocular geometry were associated with greater peripheral reach of the Clarus system, while no statistically supported advantage for Optos is observed in shorter or hyperopic eyes. Overall, the Clarus 500 and Optos Daytona provide comparable peripheral visualization in most retinal quadrants. These findings should be interpreted in the context of the exploratory study design.

BMC Ophthalmology
Vienna Institute for Research in Ocular Surgery (AT)
Openalex Percentile: Top 18%
Retinal and Macular Surgery
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.