Panoramic hybrid transmission topology and spatially adaptive sensitivity compensation EIT: Wide-field deep imaging via dual-array

Needle-based electrical impedance tomography (EIT) is a crucial modality for the real-time monitoring of irreversible electroporation (IRE) in deep-seated tumors. However, under the conventional adjacent drive pattern, the effective field of view is physically confined within the convex hull of the electrode array due to current constriction, which prevents the assessment of lateral ablation boundaries. Here, we proposed an EIT paradigm integrating a panoramic hybrid transmission topology with spatially adaptive sensitivity compensation (SASC). Guided by the principle of minimum power dissipation, trans-array distal current injection is used to activate fringing fields, which forces current penetration beyond the periphery of the array. Concurrently, the SASC strategy that uses virtual aperture synthesis is developed to counteract the suppression of weak far-field signals inherent in conventional regularization algorithms. Numerical simulations conducted on three circular inclusions with a radius of 2.5 mm (left exterior x = 5 mm, central x = 15 mm, right exterior x = 25 mm) verified that the proposed method distinctly resolves all targets and achieves uniform normalized amplitudes across the panoramic FOV, with the contrast of targets outside the convex hull being comparable to that of the central inclusions. Importantly, the method maintains stable, high-fidelity performance under 30 dB of noise, a level typical of clinical intraoperative environments, and exhibits excellent anti-noise robustness across the entire imaging domain. This approach preserves high central resolution while transforming a localized probe into a panoramic imager and provides a robust technical foundation for real-time assessment of safety boundaries during large-volume IRE ablation.

Authors

Institutions

Publication Details

Journal
Applied Physics Letters
Published
2026-04-06
DOI
https://doi.org/10.1063/5.0320664
Primary Topic
Electrical and Bioimpedance Tomography
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Panoramic hybrid transmission topology and spatially adaptive sensitivity compensation EIT: Wide-field deep imaging via dual-array

Yiran Shu, Chenguo Yao, Shoulong Dong
Applied Physics Letters
Electrical and Bioimpedance Tomography
article

Panoramic hybrid transmission topology and spatially adaptive sensitivity compensation EIT: Wide-field deep imaging via dual-array

Yiran Shu, Chenguo Yao, Shoulong Dong
article en

Abstract

Needle-based electrical impedance tomography (EIT) is a crucial modality for the real-time monitoring of irreversible electroporation (IRE) in deep-seated tumors. However, under the conventional adjacent drive pattern, the effective field of view is physically confined within the convex hull of the electrode array due to current constriction, which prevents the assessment of lateral ablation boundaries. Here, we proposed an EIT paradigm integrating a panoramic hybrid transmission topology with spatially adaptive sensitivity compensation (SASC). Guided by the principle of minimum power dissipation, trans-array distal current injection is used to activate fringing fields, which forces current penetration beyond the periphery of the array. Concurrently, the SASC strategy that uses virtual aperture synthesis is developed to counteract the suppression of weak far-field signals inherent in conventional regularization algorithms. Numerical simulations conducted on three circular inclusions with a radius of 2.5 mm (left exterior x = 5 mm, central x = 15 mm, right exterior x = 25 mm) verified that the proposed method distinctly resolves all targets and achieves uniform normalized amplitudes across the panoramic FOV, with the contrast of targets outside the convex hull being comparable to that of the central inclusions. Importantly, the method maintains stable, high-fidelity performance under 30 dB of noise, a level typical of clinical intraoperative environments, and exhibits excellent anti-noise robustness across the entire imaging domain. This approach preserves high central resolution while transforming a localized probe into a panoramic imager and provides a robust technical foundation for real-time assessment of safety boundaries during large-volume IRE ablation.

Applied Physics LettersVol. 128(14)
Chongqing University (CN), Chongqing University of Technology (CN)
National Natural Science Foundation of China, Fundamental Research Funds for the Central Universities
Sustainable cities and communities
Openalex Percentile: Top 19%
Electrical and Bioimpedance Tomography
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.