Percutaneous Left Atrial Appendage Balloon-Occlusive Aspiration Thrombectomy With Subsequent Occluder Implant

BACKGROUND: There is currently no standard clinical approach to patients in need of left atrial appendage (LAA) occlusion device with persistent LAA thrombus. The steerable, balloon-tipped SafeCross transseptal introducer system provides the opportunity for a novel approach to LAA thrombectomy by blockading the LAA os with its balloon tip, creating a closed system for embolic protection during aspiration. CASE SUMMARY: Consecutive patients from the Medical University of South Carolina were included who underwent balloon-occlusive aspiration thrombectomy (BOAT) of the LAA with the SafeCross system followed by LAA occlusion device implantation. DISCUSSION: Four patients, with a mean age of 79.5 ± 4.04 years and 75% male, were included. Balloon occlusion was achieved in 75% of cases during BOAT of the LAA. All cases resulted in successful aspiration of the LAA thrombus and subsequent successful placement of Watchman FLX Pro without periprocedural complications or adverse events at 45-day follow-up. TAKE-HOME MESSAGE: Our small case series demonstrates the feasibility of performing a transseptal LAA BOAT thrombectomy with the SafeCross transseptal system to facilitate LAA occluder implant.

Authors

Institutions

Publication Details

Journal
JACC Case Reports
Published
2026-04-01
DOI
https://doi.org/10.1016/j.jaccas.2026.107817
Primary Topic
Atrial Fibrillation Management and Outcomes
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Percutaneous Left Atrial Appendage Balloon-Occlusive Aspiration Thrombectomy With Subsequent Occluder Implant

Jessica V. Kaczmarek, Nicholas Amoroso, Jacob M. Read, Daniel Steinberg
JACC Case Reports
Atrial Fibrillation Management and Outcomes
article

Percutaneous Left Atrial Appendage Balloon-Occlusive Aspiration Thrombectomy With Subsequent Occluder Implant

Jessica V. Kaczmarek, Nicholas Amoroso, Jacob M. Read, Daniel Steinberg
article en

Abstract

BACKGROUND: There is currently no standard clinical approach to patients in need of left atrial appendage (LAA) occlusion device with persistent LAA thrombus. The steerable, balloon-tipped SafeCross transseptal introducer system provides the opportunity for a novel approach to LAA thrombectomy by blockading the LAA os with its balloon tip, creating a closed system for embolic protection during aspiration. CASE SUMMARY: Consecutive patients from the Medical University of South Carolina were included who underwent balloon-occlusive aspiration thrombectomy (BOAT) of the LAA with the SafeCross system followed by LAA occlusion device implantation. DISCUSSION: Four patients, with a mean age of 79.5 ± 4.04 years and 75% male, were included. Balloon occlusion was achieved in 75% of cases during BOAT of the LAA. All cases resulted in successful aspiration of the LAA thrombus and subsequent successful placement of Watchman FLX Pro without periprocedural complications or adverse events at 45-day follow-up. TAKE-HOME MESSAGE: Our small case series demonstrates the feasibility of performing a transseptal LAA BOAT thrombectomy with the SafeCross transseptal system to facilitate LAA occluder implant.

JACC Case Reports
Medical University of South Carolina (US)
Zero hunger
Openalex Percentile: Top 22%
Atrial Fibrillation Management and Outcomes
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.