Minimizing Unintended Background Signals Arising from Conventional Mounting Techniques in Sensitive Magnetometry

Two-dimensional (2D) van der Waals materials have attracted considerable interest for nanoscale spintronic devices such as spin valves, spin-filter magnetic tunnel junctions, and magnetic field sensors. Understanding the intrinsic magnetism in these systems is essential, particularly as measurements often require ultra-sensitive magnetometry near detection limits, where artefacts and magnetic contamination can significantly affect results. Consequently, the reliability of magnetometric detection of ferromagnetism in such materials has been questioned. Here, we systematically investigate magnetic contamination introduced when Teflon or K-tape is used during sample placement for measurements and handling propose to mitigate or eliminate these artifacts. We present the temperature- and magnetic field-dependent magnetization data of 1T-TiSe₂ obtained following these procedures, which is diamagnetic in the temperature range of 5−300 K.

Authors

Publication Details

Journal
Journal of Magnetics
Published
2026-03-31
DOI
https://doi.org/10.4283/jmag.2026.31.1.103
Primary Topic
Geophysical and Geoelectrical Methods
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Minimizing Unintended Background Signals Arising from Conventional Mounting Techniques in Sensitive Magnetometry

R. S. Patel, Sharvari Kulkarni
Journal of Magnetics
Geophysical and Geoelectrical Methods
article

Minimizing Unintended Background Signals Arising from Conventional Mounting Techniques in Sensitive Magnetometry

R. S. Patel, Sharvari Kulkarni
article en

Abstract

Two-dimensional (2D) van der Waals materials have attracted considerable interest for nanoscale spintronic devices such as spin valves, spin-filter magnetic tunnel junctions, and magnetic field sensors. Understanding the intrinsic magnetism in these systems is essential, particularly as measurements often require ultra-sensitive magnetometry near detection limits, where artefacts and magnetic contamination can significantly affect results. Consequently, the reliability of magnetometric detection of ferromagnetism in such materials has been questioned. Here, we systematically investigate magnetic contamination introduced when Teflon or K-tape is used during sample placement for measurements and handling propose to mitigate or eliminate these artifacts. We present the temperature- and magnetic field-dependent magnetization data of 1T-TiSe₂ obtained following these procedures, which is diamagnetic in the temperature range of 5−300 K.

Journal of MagneticsVol. 31(1)
Climate action
Openalex Percentile: Top 4%
Geophysical and Geoelectrical Methods
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.