Aptamer‐Functionalized Silicon Nanonet‐Based Field‐Effect‐Transistors Combined with Machine Learning for Real‐Time Detection of 17β‐Estradiol

ABSTRACT Accurate monitoring of reproductive hormones is essential for the diagnosis and for improving treatment outcomes in infertility, polycystic ovary syndrome (PCOS), and other endocrine disorders. Conventional methods such as enzyme‐linked immunosorbent assay (ELISA) are reliable but often invasive, time‐consuming, and hence unsuitable for real‐time or point‐of‐care applications. We present a silicon nanonet‐based field‐effect transistor (BioFET) functionalized with DNA aptamers as a nano‐biosensing platform for discrete and real‐time detection of 17β estradiol (E2)—a key biomarker in reproductive health. The biosensor exhibits concentration‐dependent changes in drain–source current (I SD ) across E2 levels of 20–400 pg/mL in phosphate‐buffered saline, reflecting physiologically relevant conditions. Minimal responses to progesterone and testosterone (200 pg/mL) confirm high selectivity. Analysis of the transfer characteristics shows a consistent increase in I DS at fixed gate voltage with rising E2 concentration, while fluorescence microscopy verifies spatially controlled aptamer immobilization. The latter is achieved through microcontact printing, which enables patterned deposition of aptamers onto the 3‐triethoxysilylpropylsuccinic anhydride (TESPSA)‐functionalized silicon surface with high spatial precision. Real‐time monitoring at the gate voltage (V G ) of 1.5 V enables dynamic tracking of hormone levels and partial signal reversibility after NaCl‐induced dissociation. Machine learning (ML) models applied to the time‐series biosensor data enable accurate prediction of E2 concentrations. These results emphasize the high potential of aptamer‐based BioFETs, particularly when integrated with data‐driven analysis, for non‐invasive and real‐time hormone monitoring in fertility care.

Authors

Institutions

Publication Details

Journal
Advanced Sensor Research
Published
2026-04-01
DOI
https://doi.org/10.1002/adsr.202500171
Citations
1
Primary Topic
Nanowire Synthesis and Applications
Type
article
Field-Weighted Citation Impact
9.92
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Aptamer‐Functionalized Silicon Nanonet‐Based Field‐Effect‐Transistors Combined with Machine Learning for Real‐Time Detection of 17β‐Estradiol

Shirong Huang, Gianaurelio Cuniberti, Anastasiia Gorelova, Leif Riemenschneider et al.
1 citations
Advanced Sensor Research
Nanowire Synthesis and Applications
9.92
article

Aptamer‐Functionalized Silicon Nanonet‐Based Field‐Effect‐Transistors Combined with Machine Learning for Real‐Time Detection of 17β‐Estradiol

Shirong Huang, Gianaurelio Cuniberti, Anastasiia Gorelova, Leif Riemenschneider, Bergoi Ibarlucea, Alexandra Parichenko, Stephanie Klinghammer, Santiago Meliá, Chenchen Wang, Wiana Butko
article en
1 citations

Abstract

ABSTRACT Accurate monitoring of reproductive hormones is essential for the diagnosis and for improving treatment outcomes in infertility, polycystic ovary syndrome (PCOS), and other endocrine disorders. Conventional methods such as enzyme‐linked immunosorbent assay (ELISA) are reliable but often invasive, time‐consuming, and hence unsuitable for real‐time or point‐of‐care applications. We present a silicon nanonet‐based field‐effect transistor (BioFET) functionalized with DNA aptamers as a nano‐biosensing platform for discrete and real‐time detection of 17β estradiol (E2)—a key biomarker in reproductive health. The biosensor exhibits concentration‐dependent changes in drain–source current (I SD ) across E2 levels of 20–400 pg/mL in phosphate‐buffered saline, reflecting physiologically relevant conditions. Minimal responses to progesterone and testosterone (200 pg/mL) confirm high selectivity. Analysis of the transfer characteristics shows a consistent increase in I DS at fixed gate voltage with rising E2 concentration, while fluorescence microscopy verifies spatially controlled aptamer immobilization. The latter is achieved through microcontact printing, which enables patterned deposition of aptamers onto the 3‐triethoxysilylpropylsuccinic anhydride (TESPSA)‐functionalized silicon surface with high spatial precision. Real‐time monitoring at the gate voltage (V G ) of 1.5 V enables dynamic tracking of hormone levels and partial signal reversibility after NaCl‐induced dissociation. Machine learning (ML) models applied to the time‐series biosensor data enable accurate prediction of E2 concentrations. These results emphasize the high potential of aptamer‐based BioFETs, particularly when integrated with data‐driven analysis, for non‐invasive and real‐time hormone monitoring in fertility care.

Advanced Sensor ResearchVol. 5(4)
University of Alicante (ES), Max Bergmann Zentrum für Biomaterialien (DE), Tecnalia (ES)
Openalex Percentile: Top 2%
Nanowire Synthesis and Applications
9.92
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.