Analysis of the Safety of Single‐Center Contrast‐Enhanced Ultrasound in Pediatric Patients
This study retrospectively analyzed the safety of sulfur hexafluoride microbubble contrast-enhanced ultrasound (CEUS) in 447 pediatric patients (median age 8 years 4 months) at a single center. Using weight-based dosing (≤ 0.03 mL/kg of SonoVue), the overall adverse event incidence was 1.6% (7/447). Events included nausea/vomiting, severe cough, headache, rash, and transient hypertension, all mild and transient with no serious outcomes. All seven events were classified as mild, and no serious adverse events (e.g., anaphylactic shock, laryngeal edema) occurred in this study. No significant differences were found across gender or age groups. With standardized procedure and monitoring, CEUS demonstrated a highly favorable safety profile as a valuable radiation-free imaging tool in pediatrics.
Authors
- Xingpeng Fu
- Jingjing Qian (ORCID: https://orcid.org/0000-0003-4624-9963)
- Xiuzhen Yang
- Lanxin SONG
- Qingiming Liu
- Zhisu Lv
- Jingjing Ye
- Jin Yu
- Xiaoying Liu
- Junjian Li
Institutions
- Children's Hospital of Zhejiang University (CN)
Publication Details
- Journal
- Journal of Clinical Ultrasound
- Published
- 2026-04-06
- DOI
- https://doi.org/10.1002/jcu.70243
- Primary Topic
- Ultrasound and Hyperthermia Applications
- Type
- article
- Field-Weighted Citation Impact
- 0.00