A Cheonjiin Layout Mental Speller: Developing a Simple and Cost-Effective EEG-Based Brain–Computer Interface System

A brain-computer interface (BCI) enables direct communication between the brain and external devices by translating neural activity into executable control commands. Among electroencephalography (EEG)-based paradigms, steady-state visual evoked potential (SSVEP) is widely adopted due to its high signal-to-noise ratio, robustness, and minimal calibration requirements. While SSVEP-based spellers have been extensively investigated, many existing systems rely on high-channel-density EEG recordings and computationally complex processing pipelines, and are primarily designed for alphabetic input structures. In this study, we present an SSVEP-based Korean speller that integrates the Cheonjiin keyboard layout to support intuitive composition of Hangul syllables. The proposed system adopts a simple configuration, employing only five visual stimulation frequencies (6.67-12 Hz) and two occipital EEG channels (O1 and O2), with real-time frequency recognition performed using canonical correlation analysis (CCA) within a 1.5 s sliding window. EEG signals were acquired at 200 Hz using an OpenBCI Ganglion board, band-pass filtered (5-45 Hz), and processed with harmonic sinusoidal reference templates for multi-frequency classification. The proposed interface generates five control commands (up, down, left, right, and select), enabling directional cursor navigation and character confirmation on a 4 × 4 virtual Cheonjiin keyboard. Experimental validation with three healthy participants demonstrated an average classification accuracy of approximately 82% and an information transfer rate (ITR) of 31.2 bits/min. Frequency-domain analysis revealed clear spectral peaks at the stimulation frequencies and their harmonics, indicating reliable SSVEP responses. The proposed system employs a simple two-channel configuration integrated with a Korean language-specific input structure, demonstrating that reliable SSVEP-based communication can be realized without computationally intensive algorithms or high-cost EEG acquisition systems. These findings demonstrate that reliable SSVEP-based communication can be achieved using a low-channel configuration without reliance on high-cost EEG equipment.

Authors

Institutions

Publication Details

Journal
Sensors
Published
2026-04-07
DOI
https://doi.org/10.3390/s26072265
Primary Topic
EEG and Brain-Computer Interfaces
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Cheonjiin Layout Mental Speller: Developing a Simple and Cost-Effective EEG-Based Brain–Computer Interface System

Jaeun Ahn, Seung Ho Choi, Kyung-Min Byun, G.Y. Yu et al.
Sensors
EEG and Brain-Computer Interfaces
article

A Cheonjiin Layout Mental Speller: Developing a Simple and Cost-Effective EEG-Based Brain–Computer Interface System

Jaeun Ahn, Seung Ho Choi, Kyung-Min Byun, G.Y. Yu, Young-Seek Seok, Seong-Wan Kim
article en

Abstract

A brain-computer interface (BCI) enables direct communication between the brain and external devices by translating neural activity into executable control commands. Among electroencephalography (EEG)-based paradigms, steady-state visual evoked potential (SSVEP) is widely adopted due to its high signal-to-noise ratio, robustness, and minimal calibration requirements. While SSVEP-based spellers have been extensively investigated, many existing systems rely on high-channel-density EEG recordings and computationally complex processing pipelines, and are primarily designed for alphabetic input structures. In this study, we present an SSVEP-based Korean speller that integrates the Cheonjiin keyboard layout to support intuitive composition of Hangul syllables. The proposed system adopts a simple configuration, employing only five visual stimulation frequencies (6.67-12 Hz) and two occipital EEG channels (O1 and O2), with real-time frequency recognition performed using canonical correlation analysis (CCA) within a 1.5 s sliding window. EEG signals were acquired at 200 Hz using an OpenBCI Ganglion board, band-pass filtered (5-45 Hz), and processed with harmonic sinusoidal reference templates for multi-frequency classification. The proposed interface generates five control commands (up, down, left, right, and select), enabling directional cursor navigation and character confirmation on a 4 × 4 virtual Cheonjiin keyboard. Experimental validation with three healthy participants demonstrated an average classification accuracy of approximately 82% and an information transfer rate (ITR) of 31.2 bits/min. Frequency-domain analysis revealed clear spectral peaks at the stimulation frequencies and their harmonics, indicating reliable SSVEP responses. The proposed system employs a simple two-channel configuration integrated with a Korean language-specific input structure, demonstrating that reliable SSVEP-based communication can be realized without computationally intensive algorithms or high-cost EEG acquisition systems. These findings demonstrate that reliable SSVEP-based communication can be achieved using a low-channel configuration without reliance on high-cost EEG equipment.

SensorsVol. 26(7)
Yonsei University (KR), Rural Development Administration (KR), Kyung Hee University (KR)
Rural Development Administration, Ministry of Science and ICT, South Korea
Quality Education
Openalex Percentile: Top 30%
EEG and Brain-Computer Interfaces
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.