Experimental study on the seismic performance of thin-walled CFST superimposed shear walls with different column widths

Prefabricated concrete-filled steel tube shear walls leverage the advantages of both concrete and steel and have found applications in high-rise buildings and regions with high seismic activity. This paper proposes a type of thin-walled concrete-filled steel tube with superimposed shear walls (CFST-SSWs) that can be conveniently installed on-site to improve construction efficiency and quality. Four full-scale specimens were experimentally tested under constant axial forces and lateral cyclic loads to examine their seismic performance. The two main variables during tests were the end column type and the CFST column width. The X-shaped crack in the CFST-SSWs specimen only extended to the edge of the superimposed wall, while that of the cast-in-place concrete column composite shear wall specimen connected to a crack in the end column. As the widths of the CFST column increased, the ductility increased to 13.47%, and the bearing capacity increased by an average of 14.5%. The average ductility coefficients of the specimens ranged from 2.23 to 3.95, and the CFST-SSWs showed moderate ductility. Increasing the width of the CFST column had little effect on its overall energy dissipation capacity in the early stage, but helped slow the stiffness degradation and intensity degradation of CFST-SSWs. It also significantly increased the ultimate inter-story displacement angle. A calculation model was developed to predict the CFST-SSWs’ cracking load, and experimental data were used to validate the model’s accuracy.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2026-04-07
DOI
https://doi.org/10.1038/s41598-026-46555-1
Primary Topic
Structural Load-Bearing Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Experimental study on the seismic performance of thin-walled CFST superimposed shear walls with different column widths

Mengqi Gao, Chenyu Lv, Pengying Wang, Hetao Hou et al.
Scientific Reports
Structural Load-Bearing Analysis
article

Experimental study on the seismic performance of thin-walled CFST superimposed shear walls with different column widths

Mengqi Gao, Chenyu Lv, Pengying Wang, Hetao Hou, Chunliang Zhang, Shibo Wang
article en

Abstract

Prefabricated concrete-filled steel tube shear walls leverage the advantages of both concrete and steel and have found applications in high-rise buildings and regions with high seismic activity. This paper proposes a type of thin-walled concrete-filled steel tube with superimposed shear walls (CFST-SSWs) that can be conveniently installed on-site to improve construction efficiency and quality. Four full-scale specimens were experimentally tested under constant axial forces and lateral cyclic loads to examine their seismic performance. The two main variables during tests were the end column type and the CFST column width. The X-shaped crack in the CFST-SSWs specimen only extended to the edge of the superimposed wall, while that of the cast-in-place concrete column composite shear wall specimen connected to a crack in the end column. As the widths of the CFST column increased, the ductility increased to 13.47%, and the bearing capacity increased by an average of 14.5%. The average ductility coefficients of the specimens ranged from 2.23 to 3.95, and the CFST-SSWs showed moderate ductility. Increasing the width of the CFST column had little effect on its overall energy dissipation capacity in the early stage, but helped slow the stiffness degradation and intensity degradation of CFST-SSWs. It also significantly increased the ultimate inter-story displacement angle. A calculation model was developed to predict the CFST-SSWs’ cracking load, and experimental data were used to validate the model’s accuracy.

Scientific Reports
Shandong University (CN), Henan University of Engineering (CN), Chongqing Construction Engineering Investment Holding (China) (CN), Shandong Institute for Product Quality Inspection (CN), Henan Provincial Institute of Communications Planning Survey & Design (China) (CN), Henan Institute of Geological Survey (CN)
Sustainable cities and communities
Openalex Percentile: Top 9%
Structural Load-Bearing Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.