Comparison of Visual Performance Among Two Multifocal–Extended Depth-of-Focus Intraocular Lens Types and a Trifocal Intraocular Lens

PURPOSE: To compare the visual performance of a new multifocal-extended depth-of-focus (EDOF) intraocular lens (IOL) (TECNIS Odyssey, Johnson & Johnson) with that of an earlier multifocal-EDOF IOL (TECNIS Synergy; Johnson & Johnson) and a trifocal IOL (PanOptix; Alcon Laboratories, Inc). METHODS: Ninety eyes of 90 patients who received one of two types of multifocal-EDOF IOLs or a trifocal IOL were enrolled. Uncorrected and corrected distance visual acuity at various distances, photopic and mesopic contrast visual acuity, and degree of photic symptoms were evaluated at 3 months postoperatively and compared among groups. RESULTS: ⩽ .040). CONCLUSIONS: The Odyssey provided better uncorrected far and intermediate visual acuities from infinity to 1 m than the other IOLs despite no significant difference in distance-corrected visual acuity. However, it showed worse uncorrected and distance-corrected near visual acuity and intermediate visual acuities at 0.5 m, suggesting that the Odyssey has far-dominant properties and greater tolerance to refractive errors.

Authors

Institutions

Publication Details

Journal
Journal of Refractive Surgery
Published
2026-04-01
DOI
https://doi.org/10.3928/1081597x-20260212-01
Primary Topic
Ophthalmology and Visual Impairment Studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comparison of Visual Performance Among Two Multifocal–Extended Depth-of-Focus Intraocular Lens Types and a Trifocal Intraocular Lens

Koichi Uno, Shunsuke Hayashi, Motoaki Yoshida, Ken Hayashi
Journal of Refractive Surgery
Ophthalmology and Visual Impairment Studies
article

Comparison of Visual Performance Among Two Multifocal–Extended Depth-of-Focus Intraocular Lens Types and a Trifocal Intraocular Lens

Koichi Uno, Shunsuke Hayashi, Motoaki Yoshida, Ken Hayashi
article en

Abstract

PURPOSE: To compare the visual performance of a new multifocal-extended depth-of-focus (EDOF) intraocular lens (IOL) (TECNIS Odyssey, Johnson & Johnson) with that of an earlier multifocal-EDOF IOL (TECNIS Synergy; Johnson & Johnson) and a trifocal IOL (PanOptix; Alcon Laboratories, Inc). METHODS: Ninety eyes of 90 patients who received one of two types of multifocal-EDOF IOLs or a trifocal IOL were enrolled. Uncorrected and corrected distance visual acuity at various distances, photopic and mesopic contrast visual acuity, and degree of photic symptoms were evaluated at 3 months postoperatively and compared among groups. RESULTS: ⩽ .040). CONCLUSIONS: The Odyssey provided better uncorrected far and intermediate visual acuities from infinity to 1 m than the other IOLs despite no significant difference in distance-corrected visual acuity. However, it showed worse uncorrected and distance-corrected near visual acuity and intermediate visual acuities at 0.5 m, suggesting that the Odyssey has far-dominant properties and greater tolerance to refractive errors.

Journal of Refractive SurgeryVol. 42(4)
Hayashi Eye Hospital (JP)
Openalex Percentile: Top 28%
Ophthalmology and Visual Impairment Studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.