Achieving Effective Batch-to-Batch Error Correction through Suppression Correction and Dual MSTUS Normalization

was treated with four different oxidants at five different time points. Biologically replicated sample sets were analyzed across six batches where the batch effect was intentionally introduced. We used the Isotopic Ratio Outlier Analysis (IROA) workflow method to first correct suppressed raw MS data for source related errors and then subsequently applied an enhanced normalization technique. These results were compared to those of other widely used normalization methods. Importantly, for validation of our approach, we conducted careful statistical evaluation and biological validation to ensure that the correction had effectively removed batch effects without losing biological signal. This workflow method could successfully distinguish between technical and biological variation and reduce the relative standard deviation (RSD) error to 1% compared to raw data, a clear indication that this method can be used to reliably enhance data quality. The experimental design afforded us with a means to test the ability of each normalization method to correctly group similar samples in a "data fidelity test" that may have utility for future studies.

Authors

Institutions

Publication Details

Journal
Analytical Chemistry
Published
2026-04-07
DOI
https://doi.org/10.1021/acs.analchem.5c05210
Primary Topic
Pesticide Residue Analysis and Safety
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Achieving Effective Batch-to-Batch Error Correction through Suppression Correction and Dual MSTUS Normalization

Felice A. de Jong, Vladimir Shulaev, Chris A. Beecher, Debasish Ghosh et al.
Analytical Chemistry
Pesticide Residue Analysis and Safety
article

Achieving Effective Batch-to-Batch Error Correction through Suppression Correction and Dual MSTUS Normalization

Felice A. de Jong, Vladimir Shulaev, Chris A. Beecher, Debasish Ghosh, Janmejoy Kar
article en

Abstract

was treated with four different oxidants at five different time points. Biologically replicated sample sets were analyzed across six batches where the batch effect was intentionally introduced. We used the Isotopic Ratio Outlier Analysis (IROA) workflow method to first correct suppressed raw MS data for source related errors and then subsequently applied an enhanced normalization technique. These results were compared to those of other widely used normalization methods. Importantly, for validation of our approach, we conducted careful statistical evaluation and biological validation to ensure that the correction had effectively removed batch effects without losing biological signal. This workflow method could successfully distinguish between technical and biological variation and reduce the relative standard deviation (RSD) error to 1% compared to raw data, a clear indication that this method can be used to reliably enhance data quality. The experimental design afforded us with a means to test the ability of each normalization method to correctly group similar samples in a "data fidelity test" that may have utility for future studies.

Analytical ChemistryVol. 98(15)
University of North Texas (US), ReliaCoat Technologies (United States) (US), Advanced Research Institute (US), OCP Group (Morocco) (MA), Advanced Medical Research Institute (US)
Openalex Percentile: Top 28%
Pesticide Residue Analysis and Safety
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.