Intramedullary Nail-Guided Correction of Lower Extremity Long Bone Deformity: Technique and Case Series

Introduction Limb deformities of the lower extremity are frequently managed with gradual correction using external fixators. Some authors have described utilizing computer-assisted hexapod external fixators for precise intraoperative Deformity Correction (DC). However, external fixator correction is both costly and time-intensive, and intramedullary nail-guided correction (IMNG) may be an acceptable alternative. The purpose of this study was to assess the efficacy of IMNG as a non-inferior cost-effective alternative approach to lower extremity long bone DC. Methods All patients who underwent femoral or tibial IMNG at a single institution from 2006 to 2022 were retrospectively reviewed. Pre- and postoperative deformity measurements, including Mechanical Axis Deviation (MAD), Lateral Distal Femoral Angle (LDFA), Medial Proximal Tibial Angle (MPTA), and Lateral Distal Tibial Angle (LDTA), were recorded using standing hip-to-ankle radiographs. Radiographic and clinical outcomes were recorded. Results Twenty-four IMNG Deformity Correction (DC) procedures performed on 18 patients were included [10 (56%) female, mean age 30 (15-62) years, mean body mass index 31 (21-67) kg/m 2 , mean follow-up 36 (9-111) months]. There were 10 (45%) isolated femoral DC, 10 (45%) isolated tibial DC, and 2 (9%) ipsilateral femoral and tibial DC in a single operation. All patients were followed until clinical and radiographic union. Mean MAD was corrected from 42.5 ± 35.0 mm preoperatively to 10.2 ± 4.8 mm from the targeted MAD. Complications occurred in 9 (50%) patients, predominantly related to symptomatic hardware and delayed healing. The rate of soft tissue complications was 5.6%. Discussion The IMNG achieved accurate correction with lower rates of soft tissue complications compared to computer-assisted hexapod fixators. Furthermore, the rate of hardware removal with IMNG was approximately half of that seen with external fixator methods. Conclusion IMNG correction is an effective and cost-conscious technique to correct complex long bone deformities of the femur and tibia.

Authors

Institutions

Publication Details

Journal
The Open Orthopaedics Journal
Published
2026-04-07
DOI
https://doi.org/10.2174/0118743250427357260331070703
Primary Topic
Bone fractures and treatments
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Intramedullary Nail-Guided Correction of Lower Extremity Long Bone Deformity: Technique and Case Series

Ankur Khanna, A. Thompson, Megan L. Anderson, Brandon J. Yuan et al.
The Open Orthopaedics Journal
Bone fractures and treatments
article

Intramedullary Nail-Guided Correction of Lower Extremity Long Bone Deformity: Technique and Case Series

Ankur Khanna, A. Thompson, Megan L. Anderson, Brandon J. Yuan, Jennifer Tangtiphaiboontana, William W. Cross, S. Andrew Sems, Krystin A. Hidden
article en

Abstract

Introduction Limb deformities of the lower extremity are frequently managed with gradual correction using external fixators. Some authors have described utilizing computer-assisted hexapod external fixators for precise intraoperative Deformity Correction (DC). However, external fixator correction is both costly and time-intensive, and intramedullary nail-guided correction (IMNG) may be an acceptable alternative. The purpose of this study was to assess the efficacy of IMNG as a non-inferior cost-effective alternative approach to lower extremity long bone DC. Methods All patients who underwent femoral or tibial IMNG at a single institution from 2006 to 2022 were retrospectively reviewed. Pre- and postoperative deformity measurements, including Mechanical Axis Deviation (MAD), Lateral Distal Femoral Angle (LDFA), Medial Proximal Tibial Angle (MPTA), and Lateral Distal Tibial Angle (LDTA), were recorded using standing hip-to-ankle radiographs. Radiographic and clinical outcomes were recorded. Results Twenty-four IMNG Deformity Correction (DC) procedures performed on 18 patients were included [10 (56%) female, mean age 30 (15-62) years, mean body mass index 31 (21-67) kg/m 2 , mean follow-up 36 (9-111) months]. There were 10 (45%) isolated femoral DC, 10 (45%) isolated tibial DC, and 2 (9%) ipsilateral femoral and tibial DC in a single operation. All patients were followed until clinical and radiographic union. Mean MAD was corrected from 42.5 ± 35.0 mm preoperatively to 10.2 ± 4.8 mm from the targeted MAD. Complications occurred in 9 (50%) patients, predominantly related to symptomatic hardware and delayed healing. The rate of soft tissue complications was 5.6%. Discussion The IMNG achieved accurate correction with lower rates of soft tissue complications compared to computer-assisted hexapod fixators. Furthermore, the rate of hardware removal with IMNG was approximately half of that seen with external fixator methods. Conclusion IMNG correction is an effective and cost-conscious technique to correct complex long bone deformities of the femur and tibia.

The Open Orthopaedics JournalVol. 20(1)
Mayo Clinic (US), Mayo Clinic in Arizona (US), Mayo Clinic in Florida (US)
Openalex Percentile: Top 28%
Bone fractures and treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.