Biomechanical Study of Load to Failure of a Bone Model After Removal of a 2.7-mm or 3.5-mm Plate

Objective This study aimed to investigate the impact of screw hole size on the mechanical strength of bone models following construct removal. Methods A locking plate and screws were applied to 34 cylindrical bone models. Seventeen (50%) models were assigned to receive a six-hole plate with 6 3.5-mm screws, and seventeen (50%) models were assigned to receive a ten-hole plate with 8 2.7-mm screws. The screws were subsequently removed, and each model underwent three-point bending and compression tests until bone model failure. Non-inferiority analysis was performed comparing the maximum failure load of the 3.5-mm construct to the 2.7-mm construct. A non-inferiority limit was set at a 10% reduction in the 2.7-mm bone model mean maximum failure load for both the compression and three-point bending tests. Results For three-point bend testing, the six-hole 3.5-mm construct was found to be non-inferior to the eight-hole 2.7-mm construct (2145.56 ± 141.04 N versus 2228.37 ± 174.93 N). For compression testing, the 3.5-mm construct cohort was non-inferior to the 2.7-mm construct cohort (14097.73 ± 686.88 N versus 14782.31 ± 841.95 N). Conclusion Our bone model data suggest that the biomechanical strength of bone following 3.5-mm construct removal is non-inferior to the biomechanical strength of bone following 2.7-mm construct removal. When selecting fixation that may be later removed, surgeons should choose plate constructs for open reduction and internal fixation that are suited to the fracture fixation without concern that screw hole size affects the biomechanical strength of the bone after hardware removal.

Authors

Institutions

Publication Details

Journal
Cureus
Published
2026-04-07
DOI
https://doi.org/10.7759/cureus.106580
Primary Topic
Bone fractures and treatments
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Biomechanical Study of Load to Failure of a Bone Model After Removal of a 2.7-mm or 3.5-mm Plate

Wade von Kleeck, Devon R. Pekas, Garret Burks, Jesse Seamon et al.
Cureus
Bone fractures and treatments
article

Biomechanical Study of Load to Failure of a Bone Model After Removal of a 2.7-mm or 3.5-mm Plate

Wade von Kleeck, Devon R. Pekas, Garret Burks, Jesse Seamon, Peter J. Apel, Franco Coniglione, Cody L. Evans, Swami Rajaram
article en

Abstract

Objective This study aimed to investigate the impact of screw hole size on the mechanical strength of bone models following construct removal. Methods A locking plate and screws were applied to 34 cylindrical bone models. Seventeen (50%) models were assigned to receive a six-hole plate with 6 3.5-mm screws, and seventeen (50%) models were assigned to receive a ten-hole plate with 8 2.7-mm screws. The screws were subsequently removed, and each model underwent three-point bending and compression tests until bone model failure. Non-inferiority analysis was performed comparing the maximum failure load of the 3.5-mm construct to the 2.7-mm construct. A non-inferiority limit was set at a 10% reduction in the 2.7-mm bone model mean maximum failure load for both the compression and three-point bending tests. Results For three-point bend testing, the six-hole 3.5-mm construct was found to be non-inferior to the eight-hole 2.7-mm construct (2145.56 ± 141.04 N versus 2228.37 ± 174.93 N). For compression testing, the 3.5-mm construct cohort was non-inferior to the 2.7-mm construct cohort (14097.73 ± 686.88 N versus 14782.31 ± 841.95 N). Conclusion Our bone model data suggest that the biomechanical strength of bone following 3.5-mm construct removal is non-inferior to the biomechanical strength of bone following 2.7-mm construct removal. When selecting fixation that may be later removed, surgeons should choose plate constructs for open reduction and internal fixation that are suited to the fracture fixation without concern that screw hole size affects the biomechanical strength of the bone after hardware removal.

CureusVol. 18(4)
Carilion Clinic (US), Virginia Tech (US)
Openalex Percentile: Top 34%
Bone fractures and treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.