A peak-oriented diffusion model for high-fidelity electrocardiogram reconstruction from photoplethysmogram: development and usability study

Cardiovascular disease is a leading cause of death, accounting for nearly one-third of all fatalities worldwide. The electrocardiogram (ECG), an electrophysiological signal representing cardiac activity, is a widely used non-invasive method for diagnosing cardiovascular diseases. However, ECG has limitations for continuous monitoring due to sensor size requirements, including electrodes. The photoplethysmogram (PPG), an optical method measuring blood volume variations, offers a more convenient alternative but provides less detailed information about heart activity than ECG. We introduce a peak-oriented diffusion model for PPG-to-ECG reconstruction, utilizing a U-Net framework composed of an encoder and decoder. We aim for the model to learn the peak differences between ECG and PPG by predicting R peaks from the systolic peaks of PPG, thereby preserving the main components of ECG signals. We evaluate the reconstructed ECG through clinical interpretation and assess it with noise input to verify model robustness under a daily environment. An R peak predictor, connected to the U-Net bottleneck, estimates R peaks incorporated into the decoder. The R peak predictor enables the model to reconstruct the ECG from the PPG while learning peak differences characterized as pulse transit time. We trained and evaluated the model using the MIMIC-III, WESAD, and PPG-DaLiA datasets. We assessed the model performance using root-mean-squared error and Fréchet distance, along with the ECG interpretation. In addition, atrial fibrillation detection and heart rate estimation are performed to verify clinical use of the reconstructed ECG. There were 59,980,410 segmented samples from 5,888 patients, split into train and test sets based on each patient, with an 8:2 ratio. The proposed model achieved a root-mean-square-error of 0.220, a Fréchet distance of 6.456, an F1-score of 0.925 for atrial fibrillation detection, and a mean difference of −0.077 [−1.877, 1.723] beats/min for heart rate estimation. Our results showed that the peak-oriented diffusion model translates PPG into high-fidelity ECG for clinical applications. We believe our findings expand the usefulness of the AI-based model to mobile healthcare, which involves continuous ECG monitoring in daily life.

Authors

Institutions

Publication Details

Journal
BioData Mining
Published
2026-04-06
DOI
https://doi.org/10.1186/s13040-026-00544-2
Primary Topic
Non-Invasive Vital Sign Monitoring
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A peak-oriented diffusion model for high-fidelity electrocardiogram reconstruction from photoplethysmogram: development and usability study

Hyun-Myung Cho, Inchan Youn, Joon‐Kyung Seong
BioData Mining
Non-Invasive Vital Sign Monitoring
article

A peak-oriented diffusion model for high-fidelity electrocardiogram reconstruction from photoplethysmogram: development and usability study

Hyun-Myung Cho, Inchan Youn, Joon‐Kyung Seong
article en

Abstract

Cardiovascular disease is a leading cause of death, accounting for nearly one-third of all fatalities worldwide. The electrocardiogram (ECG), an electrophysiological signal representing cardiac activity, is a widely used non-invasive method for diagnosing cardiovascular diseases. However, ECG has limitations for continuous monitoring due to sensor size requirements, including electrodes. The photoplethysmogram (PPG), an optical method measuring blood volume variations, offers a more convenient alternative but provides less detailed information about heart activity than ECG. We introduce a peak-oriented diffusion model for PPG-to-ECG reconstruction, utilizing a U-Net framework composed of an encoder and decoder. We aim for the model to learn the peak differences between ECG and PPG by predicting R peaks from the systolic peaks of PPG, thereby preserving the main components of ECG signals. We evaluate the reconstructed ECG through clinical interpretation and assess it with noise input to verify model robustness under a daily environment. An R peak predictor, connected to the U-Net bottleneck, estimates R peaks incorporated into the decoder. The R peak predictor enables the model to reconstruct the ECG from the PPG while learning peak differences characterized as pulse transit time. We trained and evaluated the model using the MIMIC-III, WESAD, and PPG-DaLiA datasets. We assessed the model performance using root-mean-squared error and Fréchet distance, along with the ECG interpretation. In addition, atrial fibrillation detection and heart rate estimation are performed to verify clinical use of the reconstructed ECG. There were 59,980,410 segmented samples from 5,888 patients, split into train and test sets based on each patient, with an 8:2 ratio. The proposed model achieved a root-mean-square-error of 0.220, a Fréchet distance of 6.456, an F1-score of 0.925 for atrial fibrillation detection, and a mean difference of −0.077 [−1.877, 1.723] beats/min for heart rate estimation. Our results showed that the peak-oriented diffusion model translates PPG into high-fidelity ECG for clinical applications. We believe our findings expand the usefulness of the AI-based model to mobile healthcare, which involves continuous ECG monitoring in daily life.

BioData Mining
Korea University (KR), Advanced Analysis Center (JP), Korea University (JP), Korea Institute of Science and Technology (KR)
Good health and well-being
Openalex Percentile: Top 27%
Non-Invasive Vital Sign Monitoring
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.