Optical See-Through and Video See-Through Head-Mounted Displays for Percutaneous Biopsies: A Comparative Phantom Study

PURPOSE: To compare the added benefit of optical see-through, the Magic Leap 2 (ML2), and video see-through, the Apple Vision Pro (AVP), head-mounted displays extended reality (XR) during percutaneous biopsies on an abdominal phantom. MATERIAL AND METHODS: In this phantom-based prospective cohort study, sixteen radiologists (5 experienced and 11 beginners) performed six needle insertions: two without XR, two with ML2, and two with AVP. Two lesions of differing difficulty (depth and proximity to vessels) were targeted. Post-procedure CT measured accuracy (hitting the target and distance and angle to lesion center). Cognitive workload and user experience were assessed using a structured questionnaire with a rating of 0-20. RESULTS: Beginners benefited more from XR than experienced radiologists. Beginners improved their targeting accuracy with XR, especially for the more complex lesion closer to blood vessels, where success rates increased using XR (conventional: 1/11, ML2: 2/11, AVP: 4/11), with a decrease in mean distance to target (conventional: 17.95 ± 9.14 mm; ML2: 14.21 ± 6.27 mm; AVP: 12.02 ± 7.19 mm). Advanced radiologists had overall lower success rates (conventional: 1/5, ML2: 0/5, AVP: 1/5). XR also reduced puncture time for beginner (ML2: 68.1%, AVP: 56.9% of baseline) and advanced radiologists (ML2: 79.0%, AVP: 61.7%). Questionnaire results indicated AVP was perceived as more mentally demanding, particularly by experienced radiologists (mental demand: conventional: 11, ML2: 9, AVP: 12, for beginners, and conventional: 12, ML2: 11, AVP: 17, for advanced). Beginners adapted well to both systems, showing no significant difference in perceived workload compared to conventional puncture and similar performance levels (conventional: 9, ML2: 9, AVP: 12, for beginners, and conventional: 15, ML2: 11, AVP: 7, for advanced). CONCLUSION: Our work demonstrates that AVP performs similar to ML2 in needle placement tasks and can be used in further research and clinical application in interventional radiology. LEVEL OF EVIDENCE: No level of evidence.

Authors

Institutions

Publication Details

Journal
CardioVascular and Interventional Radiology
Published
2026-04-07
DOI
https://doi.org/10.1007/s00270-026-04360-3
Primary Topic
Augmented Reality Applications
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Optical See-Through and Video See-Through Head-Mounted Displays for Percutaneous Biopsies: A Comparative Phantom Study

Marilia Voigt, Julian Alexander Luetkens, Dmitrij Kravchenko, Tatjana Dell et al.
CardioVascular and Interventional Radiology
Augmented Reality Applications
article

Optical See-Through and Video See-Through Head-Mounted Displays for Percutaneous Biopsies: A Comparative Phantom Study

Marilia Voigt, Julian Alexander Luetkens, Dmitrij Kravchenko, Tatjana Dell, Taraneh Aziz-Safaie, Claus Christian Pieper, Andreas Henkel, Narine Mesropyan, Patrick Arthur Kupczyk, Yannik C. Layer, Anna‐Maria Odenthal, Darius Kurt, Mohammed Bahaaeldin, Lukas Oelmeier, Alexander Isaak, Leon M. Bischoff, Alexander M. C. Böhner, Joseph Sieber, Alice M. Jacob, Nick Lenzen, Aileen Schmidt, Daniel Kuetting
article en

Abstract

PURPOSE: To compare the added benefit of optical see-through, the Magic Leap 2 (ML2), and video see-through, the Apple Vision Pro (AVP), head-mounted displays extended reality (XR) during percutaneous biopsies on an abdominal phantom. MATERIAL AND METHODS: In this phantom-based prospective cohort study, sixteen radiologists (5 experienced and 11 beginners) performed six needle insertions: two without XR, two with ML2, and two with AVP. Two lesions of differing difficulty (depth and proximity to vessels) were targeted. Post-procedure CT measured accuracy (hitting the target and distance and angle to lesion center). Cognitive workload and user experience were assessed using a structured questionnaire with a rating of 0-20. RESULTS: Beginners benefited more from XR than experienced radiologists. Beginners improved their targeting accuracy with XR, especially for the more complex lesion closer to blood vessels, where success rates increased using XR (conventional: 1/11, ML2: 2/11, AVP: 4/11), with a decrease in mean distance to target (conventional: 17.95 ± 9.14 mm; ML2: 14.21 ± 6.27 mm; AVP: 12.02 ± 7.19 mm). Advanced radiologists had overall lower success rates (conventional: 1/5, ML2: 0/5, AVP: 1/5). XR also reduced puncture time for beginner (ML2: 68.1%, AVP: 56.9% of baseline) and advanced radiologists (ML2: 79.0%, AVP: 61.7%). Questionnaire results indicated AVP was perceived as more mentally demanding, particularly by experienced radiologists (mental demand: conventional: 11, ML2: 9, AVP: 12, for beginners, and conventional: 12, ML2: 11, AVP: 17, for advanced). Beginners adapted well to both systems, showing no significant difference in perceived workload compared to conventional puncture and similar performance levels (conventional: 9, ML2: 9, AVP: 12, for beginners, and conventional: 15, ML2: 11, AVP: 7, for advanced). CONCLUSION: Our work demonstrates that AVP performs similar to ML2 in needle placement tasks and can be used in further research and clinical application in interventional radiology. LEVEL OF EVIDENCE: No level of evidence.

CardioVascular and Interventional RadiologyVol. 49(5)
University Hospital Bonn (DE), Klinikum Stuttgart (DE)
Ministerium für Wirtschaft, Innovation, Digitalisierung und Energie des Landes Nordrhein-Westfalen
Openalex Percentile: Top 35%
Augmented Reality Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.