Evaluation of near-field aerodynamics and gas-particle two-phase characteristics of a lab-scale CFR swirl burner derived from a 600 MWe wall-fired utility boiler under different staged-air ratios

In coal-fired boilers, maintaining stable combustion and low NO x emissions under fluctuating load conditions is a significant challenge. Air-staging technologies, which reduce secondary-air flow to control NO x emissions, can weaken the recirculation zone and compromise ignition stability. This study investigates the performance of a central fuel-rich (CFR) swirl burner under varying over-fire-air (OFA) ratios (0%, 10%, 25%) to assess its ability to balance NO x reduction with stable combustion. Through cold-flow experiments, gas-particle two-phase measurements, and full-scale industrial validation data, the study finds that the CFR burner with OFA=0-25% maintains a stable recirculation zone with a favorable size, ensuring stable ignition and efficient combustion. Key findings include: (1) The burner maintains a well-defined recirculation zone across all OFA conditions (0-25%), which is essential for ignition stability and uniform combustion; (2) Axial recirculation velocities and particle diffusion suppression effect are enhanced at OFA = 25%, leading to effective particle heating and faster burnout; (3) The optimized burner ensures ignition within 0.1-0.2 m from the burner exit, while significantly reducing NO x emissions and avoiding slagging or coking risks. These results demonstrate the burner’s potential to provide stable, low-NO x combustion, even under fluctuating load conditions, making it an ideal solution for load-following coal-fired boilers.

Authors

Institutions

Publication Details

Journal
Case Studies in Thermal Engineering
Published
2026-04-07
DOI
https://doi.org/10.1016/j.csite.2026.108030
Primary Topic
Combustion and flame dynamics
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Evaluation of near-field aerodynamics and gas-particle two-phase characteristics of a lab-scale CFR swirl burner derived from a 600 MWe wall-fired utility boiler under different staged-air ratios

Songzhen Tang, Shuguang Ti, Shanshan Deng, Zhenjian Jia et al.
Case Studies in Thermal Engineering
Combustion and flame dynamics
article

Evaluation of near-field aerodynamics and gas-particle two-phase characteristics of a lab-scale CFR swirl burner derived from a 600 MWe wall-fired utility boiler under different staged-air ratios

Songzhen Tang, Shuguang Ti, Shanshan Deng, Zhenjian Jia, Haopeng Wang, Shiyu Hu, Hao Liu, Gao Ke, Wenwen Chang
article en

Abstract

In coal-fired boilers, maintaining stable combustion and low NO x emissions under fluctuating load conditions is a significant challenge. Air-staging technologies, which reduce secondary-air flow to control NO x emissions, can weaken the recirculation zone and compromise ignition stability. This study investigates the performance of a central fuel-rich (CFR) swirl burner under varying over-fire-air (OFA) ratios (0%, 10%, 25%) to assess its ability to balance NO x reduction with stable combustion. Through cold-flow experiments, gas-particle two-phase measurements, and full-scale industrial validation data, the study finds that the CFR burner with OFA=0-25% maintains a stable recirculation zone with a favorable size, ensuring stable ignition and efficient combustion. Key findings include: (1) The burner maintains a well-defined recirculation zone across all OFA conditions (0-25%), which is essential for ignition stability and uniform combustion; (2) Axial recirculation velocities and particle diffusion suppression effect are enhanced at OFA = 25%, leading to effective particle heating and faster burnout; (3) The optimized burner ensures ignition within 0.1-0.2 m from the burner exit, while significantly reducing NO x emissions and avoiding slagging or coking risks. These results demonstrate the burner’s potential to provide stable, low-NO x combustion, even under fluctuating load conditions, making it an ideal solution for load-following coal-fired boilers.

Case Studies in Thermal EngineeringVol. 81
Harbin Institute of Technology (CN), Zhengzhou University of Light Industry (CN), Zhengzhou University (CN)
Affordable and clean energy
Openalex Percentile: Top 24%
Combustion and flame dynamics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.