A comparison of different image analysis techniques for mapping spatiotemporal pH and carbon dissolution in density-driven convection of CO2 in water

Density-driven convection enhances the carbon dissolution rate, which is significant for the geological carbon storage. This process will also influence the spatiotemporal pH and carbon concentrations of the underground fluid. To illuminate the convection mechanism, it is critical to understand the evolution of those properties within the porous media. However, determining the spatiotemporal pH and concentration within porous media is always challenging. This study employed a combination of three pH indicators that can track a wide range in pH from 4 to 9.5 in a convection experiment. Furthermore, we compared three image-processing techniques—Hue, gray-difference, and angular representation of RGB color space (ϕ,θ) —for quantifying color changes from the universal pH indicator arising from the carbon convection. The characterized colors were mapped into pH by calibrating against benchmark solutions. The comparative results demonstrate that the color quantified by the Hue technique is most robust, showing invariance to fluid thickness, camera settings, and LED luminance. In the convection experiments, it produces a continuous spatial distribution of pH and concentration level in the system. In contrast, the (ϕ,θ) and gray-difference techniques were more sensitive to environmental variations. They also have significant limitations for pH interpolation in the critical range due to their non-monotonic calibration paths. Although all methods ultimately produced similar estimates of total dissolved carbon, the Hue technique offers greater stability and universality for high-resolution, dynamic measurements of pH and carbon concentration in the convection experiments. • Integrated 3 pH indicators tracking pH from 4 to 9.5 in carbon convection. • Established the calibration curves interpolating pH from color data. • Compared three image-processing techniques for pH mapping stability. • Hue technique shows robustness in determining pH and carbon dissolution in porous media.

Authors

Institutions

Publication Details

Journal
Advances in Water Resources
Published
2026-04-07
DOI
https://doi.org/10.1016/j.advwatres.2026.105296
Primary Topic
CO2 Sequestration and Geologic Interactions
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A comparison of different image analysis techniques for mapping spatiotemporal pH and carbon dissolution in density-driven convection of CO2 in water

Eirik G. Flekkøy, Knut Jørgen Måløy, Marcel Moura, Yao Xu
Advances in Water Resources
CO2 Sequestration and Geologic Interactions
article

A comparison of different image analysis techniques for mapping spatiotemporal pH and carbon dissolution in density-driven convection of CO2 in water

Eirik G. Flekkøy, Knut Jørgen Måløy, Marcel Moura, Yao Xu
article en

Abstract

Density-driven convection enhances the carbon dissolution rate, which is significant for the geological carbon storage. This process will also influence the spatiotemporal pH and carbon concentrations of the underground fluid. To illuminate the convection mechanism, it is critical to understand the evolution of those properties within the porous media. However, determining the spatiotemporal pH and concentration within porous media is always challenging. This study employed a combination of three pH indicators that can track a wide range in pH from 4 to 9.5 in a convection experiment. Furthermore, we compared three image-processing techniques—Hue, gray-difference, and angular representation of RGB color space (ϕ,θ) —for quantifying color changes from the universal pH indicator arising from the carbon convection. The characterized colors were mapped into pH by calibrating against benchmark solutions. The comparative results demonstrate that the color quantified by the Hue technique is most robust, showing invariance to fluid thickness, camera settings, and LED luminance. In the convection experiments, it produces a continuous spatial distribution of pH and concentration level in the system. In contrast, the (ϕ,θ) and gray-difference techniques were more sensitive to environmental variations. They also have significant limitations for pH interpolation in the critical range due to their non-monotonic calibration paths. Although all methods ultimately produced similar estimates of total dissolved carbon, the Hue technique offers greater stability and universality for high-resolution, dynamic measurements of pH and carbon concentration in the convection experiments. • Integrated 3 pH indicators tracking pH from 4 to 9.5 in carbon convection. • Established the calibration curves interpolating pH from color data. • Compared three image-processing techniques for pH mapping stability. • Hue technique shows robustness in determining pH and carbon dissolution in porous media.

Advances in Water ResourcesVol. 212
University of Oslo (NO), Norwegian University of Science and Technology (NO)
Universitetet i Oslo, Norges Forskningsråd
Clean water and sanitation
Openalex Percentile: Top 20%
CO2 Sequestration and Geologic Interactions
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.