The accuracy of a 4-item hydration self-assessment model to classify urine concentration using different cut-offs

Background: Hydration is important for health and performance, but accurate self-assessment methods for active populations are limited. The study objective was to determine a model to classify by self-assessment a low vs. high 24-hour urine concentration, and to determine the accuracy of morning vs. afternoon assessments. The study describes the development and validation of a self-assessment model through exploratory modeling, using stepwise logistic regression. The aim was to determine which hydration markers predict urine specific gravity (using two different USG cut-offs: low ≤ 1.012, and high ≥ 1.020), in two intentionally overlapping 24-hour urine collections leading up to a morning and afternoon hydration self-assessment, and to assess its diagnostic accuracy based on the area under the curve (AUC). Results: = 23 recreational athletes (12% female, median age 25 years, with interquartile range of 24-32) were included. The median USG values of the 24-hour urine collections leading up to the morning and afternoon assessments, were 1.011 and 1.012, respectively. The AUC for the final model, which included self-reported fluid intake; urine frequency, volume, and color, to classify low vs. high USG, for low cut-off (≤ 1.012) was fair in the morning (0.72), and good in the afternoon (0.85), and for high cut-off (≥ 1.020) good for morning (0.81) and afternoon (0.86), respectively. Conclusion: This 4-item hydration self-assessment model classifies a low vs. high USG acceptable, with slightly higher accuracy in the afternoon. This insight may inform targeted hydration monitoring strategies in occupational settings, for example among WLFFs. Supplementary Information: The online version contains supplementary material available at 10.1186/s44410-026-00024-y.

Authors

Institutions

Publication Details

Journal
Performance Nutrition
Published
2026-04-07
DOI
https://doi.org/10.1186/s44410-026-00024-y
Primary Topic
Thermoregulation and physiological responses
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The accuracy of a 4-item hydration self-assessment model to classify urine concentration using different cut-offs

Gwyneth W. Gordon, Brooke Butterick, Kinta D. Schott, Floris C. Wardenaar et al.
Performance Nutrition
Thermoregulation and physiological responses
article

The accuracy of a 4-item hydration self-assessment model to classify urine concentration using different cut-offs

Gwyneth W. Gordon, Brooke Butterick, Kinta D. Schott, Floris C. Wardenaar, Raúl Freire, J. Burgess, Stavros A. Kavouras, Ryan Seltzer, David P. Sklar, Emily Dow, Parker Kooima, S. Gopalakrishnan, Kyle Reid, Zack Stow, Richard Remington, Brent Ruby
article en

Abstract

Background: Hydration is important for health and performance, but accurate self-assessment methods for active populations are limited. The study objective was to determine a model to classify by self-assessment a low vs. high 24-hour urine concentration, and to determine the accuracy of morning vs. afternoon assessments. The study describes the development and validation of a self-assessment model through exploratory modeling, using stepwise logistic regression. The aim was to determine which hydration markers predict urine specific gravity (using two different USG cut-offs: low ≤ 1.012, and high ≥ 1.020), in two intentionally overlapping 24-hour urine collections leading up to a morning and afternoon hydration self-assessment, and to assess its diagnostic accuracy based on the area under the curve (AUC). Results: = 23 recreational athletes (12% female, median age 25 years, with interquartile range of 24-32) were included. The median USG values of the 24-hour urine collections leading up to the morning and afternoon assessments, were 1.011 and 1.012, respectively. The AUC for the final model, which included self-reported fluid intake; urine frequency, volume, and color, to classify low vs. high USG, for low cut-off (≤ 1.012) was fair in the morning (0.72), and good in the afternoon (0.85), and for high cut-off (≥ 1.020) good for morning (0.81) and afternoon (0.86), respectively. Conclusion: This 4-item hydration self-assessment model classifies a low vs. high USG acceptable, with slightly higher accuracy in the afternoon. This insight may inform targeted hydration monitoring strategies in occupational settings, for example among WLFFs. Supplementary Information: The online version contains supplementary material available at 10.1186/s44410-026-00024-y.

Performance NutritionVol. 2(1)
US Forest Service (US), University of Arizona (US), Industrial Union of Metalworkers (DE), Arizona State University (US), University of Montana (US)
Federal Emergency Management Agency
Openalex Percentile: Top 26%
Thermoregulation and physiological responses
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.