Infectious medical waste characterization using X-ray transmission with Machine learning

In Germany, around 425,400 Mg of specially healthcare-related waste is generated annually, of which 2.4% (10,100 Mg) is infectious (EWC 18 01 03*). Its hazardous nature creates organizational and safety challenges for healthcare facilities and disposal companies, while composition and recycling potential remain largely unknown. However, standardized regulations enable systematic investigation. Aim of this study is to evaluate the potential of X-ray transmission combined with machine learning (ML) for material identification and recycling of infectious waste, while simultaneously assessing the previously unknown composition of this waste stream. To this end, n = 6,179 waste containers with infectious waste from German healthcare sector were systematically analysed at a waste disposal company in North Rhine-Westphalia under field trial conditions. For each container (30-l, 50-l or 60-l), two X-ray images from different angles, its mass, and three external images (including labels identifying the waste-generating facility type) were recorded. Eight content classes were defined and used to train a neural network for automatic content classification. Among all waste containers (58.7 Mg; 0.6% of annual German infectious waste), 50-l containers dominated (60%). Laboratory waste (67%) and medium-weight materials (57%) were the most frequent content classes, while metallic objects were rare and mainly occurred in heterogeneous batches. Containers with laboratory waste showed the highest share of homogeneous batches (89.5%) and the second-highest median mass (9.64 kg) after homogeneous batches (10.14 kg). Heterogeneous batches predominated in hospitals, whereas homogeneous batches dominated in laboratories. Overall, the study shows that X-ray transmission with ML reliably identifies homogeneous (F1 Score = 1), potentially recyclable fractions and provides the first quantitative characterization of infectious waste in Germany.

Authors

Institutions

Publication Details

Journal
Waste Management
Published
2026-04-07
DOI
https://doi.org/10.1016/j.wasman.2026.115513
Primary Topic
Healthcare and Environmental Waste Management
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Infectious medical waste characterization using X-ray transmission with Machine learning

Max Riedel, Anne-Kathrin Cassier-Woidasky, Lena-Marie Hupperich, Jim Magiera et al.
Waste Management
Healthcare and Environmental Waste Management
article

Infectious medical waste characterization using X-ray transmission with Machine learning

Max Riedel, Anne-Kathrin Cassier-Woidasky, Lena-Marie Hupperich, Jim Magiera, Anton Vielsack, Joerg Woidasky, Simon Eberle, Jessica Hoevel, Sven Ditzel
article en

Abstract

In Germany, around 425,400 Mg of specially healthcare-related waste is generated annually, of which 2.4% (10,100 Mg) is infectious (EWC 18 01 03*). Its hazardous nature creates organizational and safety challenges for healthcare facilities and disposal companies, while composition and recycling potential remain largely unknown. However, standardized regulations enable systematic investigation. Aim of this study is to evaluate the potential of X-ray transmission combined with machine learning (ML) for material identification and recycling of infectious waste, while simultaneously assessing the previously unknown composition of this waste stream. To this end, n = 6,179 waste containers with infectious waste from German healthcare sector were systematically analysed at a waste disposal company in North Rhine-Westphalia under field trial conditions. For each container (30-l, 50-l or 60-l), two X-ray images from different angles, its mass, and three external images (including labels identifying the waste-generating facility type) were recorded. Eight content classes were defined and used to train a neural network for automatic content classification. Among all waste containers (58.7 Mg; 0.6% of annual German infectious waste), 50-l containers dominated (60%). Laboratory waste (67%) and medium-weight materials (57%) were the most frequent content classes, while metallic objects were rare and mainly occurred in heterogeneous batches. Containers with laboratory waste showed the highest share of homogeneous batches (89.5%) and the second-highest median mass (9.64 kg) after homogeneous batches (10.14 kg). Heterogeneous batches predominated in hospitals, whereas homogeneous batches dominated in laboratories. Overall, the study shows that X-ray transmission with ML reliably identifies homogeneous (F1 Score = 1), potentially recyclable fractions and provides the first quantitative characterization of infectious waste in Germany.

Waste ManagementVol. 217
Pforzheim University of Applied Sciences (DE), Applied Materials (United Kingdom) (GB), Maison des Sciences sociales et des Humanités Ange Guépin (FR), Saarland University (DE)
Bundesministerium für Wirtschaft und Energie
Responsible consumption and production
Openalex Percentile: Top 26%
Healthcare and Environmental Waste Management
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.