Hybrid approach for aortic rupture during balloon coarctoplasty

We present a hybrid rescue technique for aortic rupture in a 33-year-old male who underwent balloon coarctoplasty for recoarctation, 16 years after end-to-end anastomosis for repair of coarctation. Following balloon coarctoplasty with stent deployment, the stent had to be redilated due to residual coarctation gradient, during which there was inadvertent aortic rupture and haemodynamic instability. The rupture was recognized quickly, and a balloon was inflated across the stented segment to provide a tamponade effect until definitive control of bleeding was achieved. The left carotid artery was accessed as an emergency through a cut-down, and a covered stent was deployed across the previously placed stent to seal off the perforation in the proximal descending aorta. This hybrid approach was effective and lifesaving in the face of a potentially catastrophic scenario. The patient had an uneventful recovery and continues to do well at 2 years follow-up.

Authors

Institutions

Publication Details

Journal
Multimedia Manual of Cardio-Thoracic Surgery
Published
2026-04-07
DOI
https://doi.org/10.1510/mmcts.2025.169
Primary Topic
Congenital Heart Disease Studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Hybrid approach for aortic rupture during balloon coarctoplasty

Srikanth Kasturi, Sudesh Prabhu, Sruti Rao, Suresh Pujar Venkateshacharya
Multimedia Manual of Cardio-Thoracic Surgery
Congenital Heart Disease Studies
article

Hybrid approach for aortic rupture during balloon coarctoplasty

Srikanth Kasturi, Sudesh Prabhu, Sruti Rao, Suresh Pujar Venkateshacharya
article en

Abstract

We present a hybrid rescue technique for aortic rupture in a 33-year-old male who underwent balloon coarctoplasty for recoarctation, 16 years after end-to-end anastomosis for repair of coarctation. Following balloon coarctoplasty with stent deployment, the stent had to be redilated due to residual coarctation gradient, during which there was inadvertent aortic rupture and haemodynamic instability. The rupture was recognized quickly, and a balloon was inflated across the stented segment to provide a tamponade effect until definitive control of bleeding was achieved. The left carotid artery was accessed as an emergency through a cut-down, and a covered stent was deployed across the previously placed stent to seal off the perforation in the proximal descending aorta. This hybrid approach was effective and lifesaving in the face of a potentially catastrophic scenario. The patient had an uneventful recovery and continues to do well at 2 years follow-up.

Multimedia Manual of Cardio-Thoracic SurgeryVol. 2026
Narayana Health (IN), Mayo Clinic in Arizona (US), Helen DeVos Children's Hospital (US)
Openalex Percentile: Top 25%
Congenital Heart Disease Studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.