Personalization of the Toyota Human Model for Safety (THUMS) Using Avatar-Driven Morphing for Biomechanical Simulations

Background/Objectives: This paper investigates the application of radial basis function (RBF) interpolation to adapt the Toyota Human Model for Safety (THUMS) version 6 finite element (FE) models to diverse anthropometric profiles using ANSUR II data. The research focuses on generating personalized human body models (HBMs) across 50th, 80th, and 98th percentiles for both sexes in standing and seated postures, evaluating mesh quality with quantitative metrics, and assessing posture-dependent transformations. Methods: The geometric accuracy for the standing configuration was quantified using DICE similarity coefficients and the 95th percentile Hausdorff distance (HD95). Results: While global whole-body DICE similarity averaged approximately 0.40 due to an inherent variability in distal limb positioning, regional analysis demonstrated strong volumetric overlap in the critical chest and torso regions with DICE values ranging from 0.80 to 0.88. Regional HD95 values were within 20–30 mm across most of the surface area. Surfaces distance analyses showed that more than 95% of the nodes were within ±20 mm of the target surfaces with the distribution centered near zero across all the percentiles. The mesh quality for both standing and seated morphs demonstrated low violation rates with the aspect ratio being 28% to 30%, while warpage, skewness and, Jacobian determinants were less than 15%. The seated morphs preserved anatomical alignment and posture despite mesh density differences between the postures. Conclusions: These findings indicate that the morphing process preserves anatomical fidelity while highlighting the need for further optimization to mitigate localized distortions in dynamic simulations.

Authors

Institutions

Publication Details

Journal
Biomechanics
Published
2026-04-07
DOI
https://doi.org/10.3390/biomechanics6020037
Primary Topic
Ergonomics and Musculoskeletal Disorders
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Personalization of the Toyota Human Model for Safety (THUMS) Using Avatar-Driven Morphing for Biomechanical Simulations

Reuben H. Kraft, Ann Reyes, Timothy R. DeWitt
Biomechanics
Ergonomics and Musculoskeletal Disorders
article

Personalization of the Toyota Human Model for Safety (THUMS) Using Avatar-Driven Morphing for Biomechanical Simulations

Reuben H. Kraft, Ann Reyes, Timothy R. DeWitt
article en

Abstract

Background/Objectives: This paper investigates the application of radial basis function (RBF) interpolation to adapt the Toyota Human Model for Safety (THUMS) version 6 finite element (FE) models to diverse anthropometric profiles using ANSUR II data. The research focuses on generating personalized human body models (HBMs) across 50th, 80th, and 98th percentiles for both sexes in standing and seated postures, evaluating mesh quality with quantitative metrics, and assessing posture-dependent transformations. Methods: The geometric accuracy for the standing configuration was quantified using DICE similarity coefficients and the 95th percentile Hausdorff distance (HD95). Results: While global whole-body DICE similarity averaged approximately 0.40 due to an inherent variability in distal limb positioning, regional analysis demonstrated strong volumetric overlap in the critical chest and torso regions with DICE values ranging from 0.80 to 0.88. Regional HD95 values were within 20–30 mm across most of the surface area. Surfaces distance analyses showed that more than 95% of the nodes were within ±20 mm of the target surfaces with the distribution centered near zero across all the percentiles. The mesh quality for both standing and seated morphs demonstrated low violation rates with the aspect ratio being 28% to 30%, while warpage, skewness and, Jacobian determinants were less than 15%. The seated morphs preserved anatomical alignment and posture despite mesh density differences between the postures. Conclusions: These findings indicate that the morphing process preserves anatomical fidelity while highlighting the need for further optimization to mitigate localized distortions in dynamic simulations.

BiomechanicsVol. 6(2)
Pennsylvania State University (US), Wright-Patterson Air Force Base (US)
Openalex Percentile: Top 6%
Ergonomics and Musculoskeletal Disorders
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Personalization of the Toyota Human Model for Safety (THUMS) Using Avatar-Driven Morphing for Biomechanical Simulations — Reuben H. Kraft, Ann Reyes, et al. · Biomechanics (2026) | TGRS Research Map | TGRS