Patients implanted with a leadless pacemaker after transcatheter aortic valve implantation: Results from the MITAVI prospective study

BACKGROUND: Transcatheter aortic valve implantation is a well-established clinical procedure for treating severe aortic stenosis. High-grade atrioventricular block has been reported in 10-30% of patients following transcatheter aortic valve implantation. Traditional transvenous pacemakers are associated with several potential complications, including endocarditis, lead dislodgement or fracture, pocket haematoma and tricuspid regurgitation. These risks may be mitigated with the use of leadless pacemakers. AIM: We proposed to evaluate the 1-year clinical and electrical outcomes of patients implanted with a leadless pacemaker following transcatheter aortic valve implantation. METHODS: From July 2019 to December 2022, 102 patients from four French centres who underwent transcatheter aortic valve implantation and subsequently required pacemaker implantation with a leadless pacemaker (Micra; Medtronic, Dublin, Ireland) were evaluated prospectively. RESULTS: The mean patient age was 82±9 years, and the mean baseline left ventricular ejection fraction was 58.4±10.6%. Major complications included one case of cardiac tamponade and one case of device migration. During 12-month follow-up, one patient required transvenous cardiac resynchronization therapy pacing because of severe heart failure. The all-cause death rate was 12%, and the heart failure hospitalization rate was also 12%. Compared with baseline, leadless pacemaker electrical variables improved at 1 year. Additionally, complete atrioventricular conduction restoration was observed in 38% of the cohort. CONCLUSIONS: Leadless pacemakers can be implanted in patients following transcatheter aortic valve implantation, with low complication rates and excellent electrical variables at 1-year follow-up. The need for an upgrade to a transvenous pacemaker was low (< 1%).

Authors

Institutions

Publication Details

Journal
Archives of cardiovascular diseases
Published
2026-04-01
DOI
https://doi.org/10.1016/j.acvd.2026.02.004
Primary Topic
Cardiac Valve Diseases and Treatments
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Patients implanted with a leadless pacemaker after transcatheter aortic valve implantation: Results from the MITAVI prospective study

Chekrallah Chamandi, Tarvinder Dhanjal, Marina Ureña, Madjid Boukantar et al.
Archives of cardiovascular diseases
Cardiac Valve Diseases and Treatments
article

Patients implanted with a leadless pacemaker after transcatheter aortic valve implantation: Results from the MITAVI prospective study

Chekrallah Chamandi, Tarvinder Dhanjal, Marina Ureña, Madjid Boukantar, Vincent Algalarrondo, Emmanuel Teíger, Eloi Marijon, Romain Gallet, Estelle Gandjbakhch, Jean-Philippe Collet, Nicolas Lellouche, Thibaut Moulin
article en

Abstract

BACKGROUND: Transcatheter aortic valve implantation is a well-established clinical procedure for treating severe aortic stenosis. High-grade atrioventricular block has been reported in 10-30% of patients following transcatheter aortic valve implantation. Traditional transvenous pacemakers are associated with several potential complications, including endocarditis, lead dislodgement or fracture, pocket haematoma and tricuspid regurgitation. These risks may be mitigated with the use of leadless pacemakers. AIM: We proposed to evaluate the 1-year clinical and electrical outcomes of patients implanted with a leadless pacemaker following transcatheter aortic valve implantation. METHODS: From July 2019 to December 2022, 102 patients from four French centres who underwent transcatheter aortic valve implantation and subsequently required pacemaker implantation with a leadless pacemaker (Micra; Medtronic, Dublin, Ireland) were evaluated prospectively. RESULTS: The mean patient age was 82±9 years, and the mean baseline left ventricular ejection fraction was 58.4±10.6%. Major complications included one case of cardiac tamponade and one case of device migration. During 12-month follow-up, one patient required transvenous cardiac resynchronization therapy pacing because of severe heart failure. The all-cause death rate was 12%, and the heart failure hospitalization rate was also 12%. Compared with baseline, leadless pacemaker electrical variables improved at 1 year. Additionally, complete atrioventricular conduction restoration was observed in 38% of the cohort. CONCLUSIONS: Leadless pacemakers can be implanted in patients following transcatheter aortic valve implantation, with low complication rates and excellent electrical variables at 1-year follow-up. The need for an upgrade to a transvenous pacemaker was low (< 1%).

Archives of cardiovascular diseases
Centre Hospitalier Universitaire Henri-Mondor (FR), University of Warwick (GB), Sorbonne Université (FR), Assistance Publique – Hôpitaux de Paris (FR), Hôpital Européen Georges-Pompidou (FR), Pitié-Salpêtrière Hospital (FR), Hôpitaux Universitaires Henri-Mondor (FR), Hôpital Bichat-Claude-Bernard (FR)
Medtronic
Zero hunger
Openalex Percentile: Top 29%
Cardiac Valve Diseases and Treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.