Determinants of ECG misdiagnosis of atrial fibrillation or flutter in the emergency department and their clinical implications: results from a single-center observational study

Atrial fibrillation (AF) and atrial flutter (AFL) are common arrhythmias frequently misdiagnosed. The emergency department (ED), a fast-paced environment, presents challenges for accurate ECG interpretation. This study examined whether timing of ED presentation affects diagnostic accuracy. Over five years (2019–2024), consecutive ECGs from patients discharged with AF or AFL were independently reviewed by two cardiologists. Diagnoses were classified as correct, partially correct (AF misread as AFL or vice versa), or overinterpreted (non-AF/AFL rhythms misread as AF/AFL). Arrival times were grouped into morning (07:00–15:00), afternoon (15:00–23:00), and night (23:00–07:00) shifts. Multivariable logistic regression analyzed predictors of overinterpretation. Among 2,003 patients (1,794 AF; 209 AFL), interpretations were correct in 1,780 (88.9%), partially correct in 166 (8.3%), and overinterpreted in 57 (2.8%). Overinterpretation rates were highest in the afternoon (4.3%) versus morning (2.8%) and night (0.7%) (p = 0.012). Independent predictors included afternoon arrival (OR 1.87; 95% CI 1.07–3.25; p = 0.027) and premature beats (OR 2.22; 95% CI 1.30–3.81; p < 0.001). Overinterpretation was independent of shift workload and physician experience, and resulted in inappropriate new prescriptions of rate-control agents (38.5%), antiarrhythmics (28%), and anticoagulants (56%), with minor and major bleeding occurring in 16% and 3.5% of cases, respectively. Diagnosis was revised during outpatient follow-up in only 5% of cases. Overinterpretation of AF remains a concern in the ED. Error rates did not rise during nighttime shifts, implying that factors other than clinician fatigue may underlie these mistakes.

Authors

Institutions

Publication Details

Journal
BMC Emergency Medicine
Published
2026-04-07
DOI
https://doi.org/10.1186/s12873-026-01574-z
Primary Topic
ECG Monitoring and Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Determinants of ECG misdiagnosis of atrial fibrillation or flutter in the emergency department and their clinical implications: results from a single-center observational study

Yuval Avidan, Asaf Danon, Nili Stein, Baruch Weizman et al.
BMC Emergency Medicine
ECG Monitoring and Analysis
article

Determinants of ECG misdiagnosis of atrial fibrillation or flutter in the emergency department and their clinical implications: results from a single-center observational study

Yuval Avidan, Asaf Danon, Nili Stein, Baruch Weizman, Sameer Kassem, Haim Katalan, Hani Sliman, Oded Mizrahi, Razi Khoury, Sameha Zahra
article en

Abstract

Atrial fibrillation (AF) and atrial flutter (AFL) are common arrhythmias frequently misdiagnosed. The emergency department (ED), a fast-paced environment, presents challenges for accurate ECG interpretation. This study examined whether timing of ED presentation affects diagnostic accuracy. Over five years (2019–2024), consecutive ECGs from patients discharged with AF or AFL were independently reviewed by two cardiologists. Diagnoses were classified as correct, partially correct (AF misread as AFL or vice versa), or overinterpreted (non-AF/AFL rhythms misread as AF/AFL). Arrival times were grouped into morning (07:00–15:00), afternoon (15:00–23:00), and night (23:00–07:00) shifts. Multivariable logistic regression analyzed predictors of overinterpretation. Among 2,003 patients (1,794 AF; 209 AFL), interpretations were correct in 1,780 (88.9%), partially correct in 166 (8.3%), and overinterpreted in 57 (2.8%). Overinterpretation rates were highest in the afternoon (4.3%) versus morning (2.8%) and night (0.7%) (p = 0.012). Independent predictors included afternoon arrival (OR 1.87; 95% CI 1.07–3.25; p = 0.027) and premature beats (OR 2.22; 95% CI 1.30–3.81; p < 0.001). Overinterpretation was independent of shift workload and physician experience, and resulted in inappropriate new prescriptions of rate-control agents (38.5%), antiarrhythmics (28%), and anticoagulants (56%), with minor and major bleeding occurring in 16% and 3.5% of cases, respectively. Diagnosis was revised during outpatient follow-up in only 5% of cases. Overinterpretation of AF remains a concern in the ED. Error rates did not rise during nighttime shifts, implying that factors other than clinician fatigue may underlie these mistakes.

BMC Emergency Medicine
Technion – Israel Institute of Technology (IL), Laniado Hospital (IL), Carmel Medical Center (IL)
Openalex Percentile: Top 7%
ECG Monitoring and Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.