Metal Artifact Reduction in CT Based on a Nonlinear Weighted Anisotropic TV Regularization

Metal artifact reduction (MAR) remains a long-standing challenge in computed tomography (CT) reconstruction. Metallic implants introduce inconsistencies between the acquired projection data and the ideal Radon transform, resulting in severe streaking artifacts in images reconstructed using the conventional filtered back projection (FBP) algorithm. In this work, we propose a nonlinear weighted anisotropic total variation (NWATV) regularization method to mitigate metal artifacts and improve CT image quality. The effectiveness of the NWATV method is evaluated through three experiments, and the results demonstrate that it achieves superior reconstruction performance compared to the conventional linear interpolation method, the normalized metal artifact reduction method and the anisotropic total variation (TV) regularization method.

Authors

Institutions

Publication Details

Journal
Mathematics
Published
2026-04-07
DOI
https://doi.org/10.3390/math14071230
Primary Topic
Advanced X-ray and CT Imaging
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Metal Artifact Reduction in CT Based on a Nonlinear Weighted Anisotropic TV Regularization

Yizhuang Song, Haiyang Wang (22389), Shuangyang Liu
Mathematics
Advanced X-ray and CT Imaging
article

Metal Artifact Reduction in CT Based on a Nonlinear Weighted Anisotropic TV Regularization

Yizhuang Song, Haiyang Wang (22389), Shuangyang Liu
article en

Abstract

Metal artifact reduction (MAR) remains a long-standing challenge in computed tomography (CT) reconstruction. Metallic implants introduce inconsistencies between the acquired projection data and the ideal Radon transform, resulting in severe streaking artifacts in images reconstructed using the conventional filtered back projection (FBP) algorithm. In this work, we propose a nonlinear weighted anisotropic total variation (NWATV) regularization method to mitigate metal artifacts and improve CT image quality. The effectiveness of the NWATV method is evaluated through three experiments, and the results demonstrate that it achieves superior reconstruction performance compared to the conventional linear interpolation method, the normalized metal artifact reduction method and the anisotropic total variation (TV) regularization method.

MathematicsVol. 14(7)
Shandong Normal University (CN)
National Natural Science Foundation of China
Openalex Percentile: Top 32%
Advanced X-ray and CT Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Metal Artifact Reduction in CT Based on a Nonlinear Weighted Anisotropic TV Regularization — Yizhuang Song, Haiyang Wang (22389), et al. · Mathematics (2026) | TGRS Research Map | TGRS