ITACA revisited: ion tracking apparatus with CMOS ASICs

High-pressure xenon gas TPCs with electroluminescent amplification provide detailed topological reconstruction of charged-particle trajectories, offering a distinctive two-electron signature for neutrinoless double beta decay ( $$\beta \beta 0\nu $$ β β 0 ν ) searches. We recently proposed ITACA, a detector concept that images both the electron track and the corresponding ion track. While electrons drift rapidly to the anode for standard EL imaging, the positive ions drift slowly to the cathode with millimetre-scale diffusion, allowing time to determine the event energy and barycenter and to position a movable ion detector at the projected arrival point of the ion cloud. We present a conceptual design of the ITACA detector, addressing key feasibility questions. First, we define the detector geometry and operating parameters for a 1-tonne-scale instrument at 15 bar, including a modular tiled electroluminescent structure. Second, we present the conceptual design of the Magnetically Actuated Rotor System (MARS), the mechanism that positions the ion sensor at any coordinate below the cathode, and show that the expected movement time is fast enough to retain $$\sim 93\%$$ ∼ 93 % of the drift volume for ion detection, while not significantly perturbing the gas on the scales of the ion drift. Third, we propose using a Topmetal CMOS ASIC-based ion detector, enabling real-time, 3D imaging of the ion track without the need for offline laser scanning. Finally, we estimate the sensitivity of the proposed apparatus, showing that enhanced topological discrimination from the ion track, combined with an ultra-low background design, allows exploration of $$\beta \beta 0\nu $$ β β 0 ν half-lives in excess of $$10^{28}$$ 10 28 yr.

Authors

Institutions

Publication Details

Journal
The European Physical Journal C
Published
2026-11-19
DOI
https://doi.org/10.1140/epjc/s10052-026-16602-2
Primary Topic
Particle Detector Development and Performance
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

ITACA revisited: ion tracking apparatus with CMOS ASICs

L. Arazi, G. Martínez-Lema, J. Renner, Samuele Torelli et al.
1 links
The European Physical Journal C
Particle Detector Development and Performance
article

ITACA revisited: ion tracking apparatus with CMOS ASICs

L. Arazi, G. Martínez-Lema, J. Renner, Samuele Torelli, S. R. Soleti, J. J. Gomez-Cadenas
article en

Abstract

High-pressure xenon gas TPCs with electroluminescent amplification provide detailed topological reconstruction of charged-particle trajectories, offering a distinctive two-electron signature for neutrinoless double beta decay ( $$\beta \beta 0\nu $$ β β 0 ν ) searches. We recently proposed ITACA, a detector concept that images both the electron track and the corresponding ion track. While electrons drift rapidly to the anode for standard EL imaging, the positive ions drift slowly to the cathode with millimetre-scale diffusion, allowing time to determine the event energy and barycenter and to position a movable ion detector at the projected arrival point of the ion cloud. We present a conceptual design of the ITACA detector, addressing key feasibility questions. First, we define the detector geometry and operating parameters for a 1-tonne-scale instrument at 15 bar, including a modular tiled electroluminescent structure. Second, we present the conceptual design of the Magnetically Actuated Rotor System (MARS), the mechanism that positions the ion sensor at any coordinate below the cathode, and show that the expected movement time is fast enough to retain $$\sim 93\%$$ ∼ 93 % of the drift volume for ion detection, while not significantly perturbing the gas on the scales of the ion drift. Third, we propose using a Topmetal CMOS ASIC-based ion detector, enabling real-time, 3D imaging of the ion track without the need for offline laser scanning. Finally, we estimate the sensitivity of the proposed apparatus, showing that enhanced topological discrimination from the ion track, combined with an ultra-low background design, allows exploration of $$\beta \beta 0\nu $$ β β 0 ν half-lives in excess of $$10^{28}$$ 10 28 yr.

The European Physical Journal CVol. 86(11)
Ikerbasque (ES), Ben-Gurion University of the Negev (IL), Instituto de Física Corpuscular (ES), Donostia International Physics Center (ES)
Particle Detector Development and Performance
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon