Advanced Extractables and Leachables Assessment of Microcarriers Used for Adherent Cell Cultures

The study outlines principles and workflows for a comprehensive extractables and leachables qualification trial of microcarriers for use in a cell therapy application. Styrene-based MCs were qualitatively and quantitatively analyzed in accordance with USP 〈665〉, followed by a kinetic investigation. Extractables data were fitted to an algorithm to enable reconstructive modeling of dynamic experimental data for both stable and degradable extractables. In a subsequent step, the temporal exposure to process equipment-related leachables (PERLs) was modeled for MCs used in a hypothetical cell therapy application with partial and continuous medium exchange. The results demonstrated that, in a dynamic environment, the release of PERLs from MCs in a perfused system does not influence product quality at levels that would pose a patient safety risk. Furthermore, process concentrations remain significantly below exposure levels that could have detrimental effects on therapeutic human cells. This demonstrates the benefits of perfused systems, or systems with partial medium exchange, as the washout effect dominates PERL release rates. PERL concentrations in such dynamic systems will always be significantly lower than PERL equilibrium concentrations under static, stagnant conditions.

Authors

Institutions

Publication Details

Journal
Biotechnology Journal
Published
2026-04-01
DOI
https://doi.org/10.1002/biot.70220
Primary Topic
Safe Handling of Antineoplastic Drugs
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Advanced Extractables and Leachables Assessment of Microcarriers Used for Adherent Cell Cultures

Armin Hauk, Ina Pahl, Roberto Menzel, Jonas Austerjost et al.
Biotechnology Journal
Safe Handling of Antineoplastic Drugs
article

Advanced Extractables and Leachables Assessment of Microcarriers Used for Adherent Cell Cultures

Armin Hauk, Ina Pahl, Roberto Menzel, Jonas Austerjost, Antonina Lavrentieva, Julia Hupfeld, Julia Bernfeld
article en

Abstract

The study outlines principles and workflows for a comprehensive extractables and leachables qualification trial of microcarriers for use in a cell therapy application. Styrene-based MCs were qualitatively and quantitatively analyzed in accordance with USP 〈665〉, followed by a kinetic investigation. Extractables data were fitted to an algorithm to enable reconstructive modeling of dynamic experimental data for both stable and degradable extractables. In a subsequent step, the temporal exposure to process equipment-related leachables (PERLs) was modeled for MCs used in a hypothetical cell therapy application with partial and continuous medium exchange. The results demonstrated that, in a dynamic environment, the release of PERLs from MCs in a perfused system does not influence product quality at levels that would pose a patient safety risk. Furthermore, process concentrations remain significantly below exposure levels that could have detrimental effects on therapeutic human cells. This demonstrates the benefits of perfused systems, or systems with partial medium exchange, as the washout effect dominates PERL release rates. PERL concentrations in such dynamic systems will always be significantly lower than PERL equilibrium concentrations under static, stagnant conditions.

Biotechnology JournalVol. 21(4)
Leibniz University Hannover (DE), Sartorius (Germany) (DE)
Openalex Percentile: Top 30%
Safe Handling of Antineoplastic Drugs
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Advanced Extractables and Leachables Assessment of Microcarriers Used for Adherent Cell Cultures — Armin Hauk, Ina Pahl, et al. · Biotechnology Journal (2026) | TGRS Research Map | TGRS