Measurement of spectra in mammography using different phantoms

Abstract Evaluation of the performance of mammographic equipment requires the imaging and interpretation of test objects or phantoms and risk assessment. This study evaluated, using a spectrometry technique, the linear attenuation coefficients determined from transmitted intensity for commercially available tissue-equivalent phantoms for mammography, namely the Computerized Imaging Reference Systems (CIRS) phantom with different glandularity–adipose contents and PMMA. The measurements were performed using X-ray beams produced by Mo/Mo, Mo/Rh, and W/Rh target/filter combinations. The results are presented for the characteristic X-ray photopeaks (Mo Kα 1 at 17.48 keV and Mo Kα 2 at 19.61 keV). Spectrometry measurements were carried out using an Amptek XR-100T Cadmium Telluride (CdTe) detector, and the spectra were corrected using MCNP6 simulations. This work demonstrates the adequacy of the results obtained for Mo Kα 1 at 17.48 keV when compared with publications that applied different methods of analysis. In addition, it presents the evaluation of the attenuation coefficient for Mo Kα 2 at 19.61 keV for the CIRS phantom and its comparison with PMMA results.

Authors

Institutions

Publication Details

Journal
The European Physical Journal Special Topics
Published
2026-04-01
DOI
https://doi.org/10.1140/epjs/s11734-026-02212-2
Primary Topic
Digital Radiography and Breast Imaging
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Measurement of spectra in mammography using different phantoms

P. M. C. de Oliveira, B. M. Mendes, P. L. Squair, M. S. Nogueira
The European Physical Journal Special Topics
Digital Radiography and Breast Imaging
article

Measurement of spectra in mammography using different phantoms

P. M. C. de Oliveira, B. M. Mendes, P. L. Squair, M. S. Nogueira
article en

Abstract

Abstract Evaluation of the performance of mammographic equipment requires the imaging and interpretation of test objects or phantoms and risk assessment. This study evaluated, using a spectrometry technique, the linear attenuation coefficients determined from transmitted intensity for commercially available tissue-equivalent phantoms for mammography, namely the Computerized Imaging Reference Systems (CIRS) phantom with different glandularity–adipose contents and PMMA. The measurements were performed using X-ray beams produced by Mo/Mo, Mo/Rh, and W/Rh target/filter combinations. The results are presented for the characteristic X-ray photopeaks (Mo Kα 1 at 17.48 keV and Mo Kα 2 at 19.61 keV). Spectrometry measurements were carried out using an Amptek XR-100T Cadmium Telluride (CdTe) detector, and the spectra were corrected using MCNP6 simulations. This work demonstrates the adequacy of the results obtained for Mo Kα 1 at 17.48 keV when compared with publications that applied different methods of analysis. In addition, it presents the evaluation of the attenuation coefficient for Mo Kα 2 at 19.61 keV for the CIRS phantom and its comparison with PMMA results.

The European Physical Journal Special TopicsVol. 235(4)
Universidade Federal de Minas Gerais (BR), Centro de Desenvolvimento da Tecnologia Nuclear (BR)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior, Conselho Nacional de Desenvolvimento Científico e Tecnológico, Fundação de Amparo à Pesquisa do Estado de Minas Gerais, Centro de Desenvolvimento da Tecnologia Nuclear
Openalex Percentile: Top 32%
Digital Radiography and Breast Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.