Biomechanical comparison of palmar plate plus headless compression screw versus radiopalmar double plating in AO/OTA 23-C2.1 distal radius fractures

This biomechanical study compared the fracture stability of a palmar plate combined with a headless compression screw (HCS) with that of a radiopalmar double-plate construct for AO/OTA 23-C2.1 distal radius fractures with metaphyseal defect zones. Eleven matched pairs of cryopreserved human radii were prepared with standardized AO/OTA 23-C2.1 fractures. Left radii (n = 11) were fixed with a palmar plate plus HCS, while right radii (n = 11) received a radiopalmar double-plate construct. Construct stiffness and axial displacement were assessed using a universal testing machine. Interfragmentary range of motion (ROM) and rotation (ROT) were quantified using an optical three-dimensional motion-tracking system. Measurements were obtained before and after 5000 cycles of dynamic axial loading at 150 N. Two specimen pairs were excluded due to early failure or incomplete data acquisition. Both constructs demonstrated comparable stiffness and axial displacement, with no implant loosening or hardware failure observed. Interfragmentary ROM did not differ significantly between groups. However, the plate–HCS construct showed greater variability in rotational parameters. Initial radial-shaft rotation was significantly greater in the plate–HCS group (1.14° vs. 0.51°, p = 0.02). After cyclic loading, ulnar-shaft rotation increased significantly in the plate–HCS group (0.97° to 1.16°, p = 0.02) but not in the double-plate group. In this cadaveric model, fixation with a palmar plate combined with an HCS provided comparable axial stability but demonstrated greater variability and less consistent rotational control compared with radiopalmar double plating. Clinical studies are required to determine whether this less invasive construct achieves equivalent outcomes in vivo.

Authors

Institutions

Publication Details

Journal
Archives of Orthopaedic and Trauma Surgery
Published
2026-04-06
DOI
https://doi.org/10.1007/s00402-026-06279-3
Primary Topic
Orthopedic Surgery and Rehabilitation
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Biomechanical comparison of palmar plate plus headless compression screw versus radiopalmar double plating in AO/OTA 23-C2.1 distal radius fractures

Ivan Zderic, Wolfram Weschenfelder, Heike Kielstein, Mark Lenz et al.
Archives of Orthopaedic and Trauma Surgery
Orthopedic Surgery and Rehabilitation
article

Biomechanical comparison of palmar plate plus headless compression screw versus radiopalmar double plating in AO/OTA 23-C2.1 distal radius fractures

Ivan Zderic, Wolfram Weschenfelder, Heike Kielstein, Mark Lenz, Christian Spiegel, F. Peter Kohler, Boyko Gueorguiev-Rüegg, Patrick Riegner
article en

Abstract

This biomechanical study compared the fracture stability of a palmar plate combined with a headless compression screw (HCS) with that of a radiopalmar double-plate construct for AO/OTA 23-C2.1 distal radius fractures with metaphyseal defect zones. Eleven matched pairs of cryopreserved human radii were prepared with standardized AO/OTA 23-C2.1 fractures. Left radii (n = 11) were fixed with a palmar plate plus HCS, while right radii (n = 11) received a radiopalmar double-plate construct. Construct stiffness and axial displacement were assessed using a universal testing machine. Interfragmentary range of motion (ROM) and rotation (ROT) were quantified using an optical three-dimensional motion-tracking system. Measurements were obtained before and after 5000 cycles of dynamic axial loading at 150 N. Two specimen pairs were excluded due to early failure or incomplete data acquisition. Both constructs demonstrated comparable stiffness and axial displacement, with no implant loosening or hardware failure observed. Interfragmentary ROM did not differ significantly between groups. However, the plate–HCS construct showed greater variability in rotational parameters. Initial radial-shaft rotation was significantly greater in the plate–HCS group (1.14° vs. 0.51°, p = 0.02). After cyclic loading, ulnar-shaft rotation increased significantly in the plate–HCS group (0.97° to 1.16°, p = 0.02) but not in the double-plate group. In this cadaveric model, fixation with a palmar plate combined with an HCS provided comparable axial stability but demonstrated greater variability and less consistent rotational control compared with radiopalmar double plating. Clinical studies are required to determine whether this less invasive construct achieves equivalent outcomes in vivo.

Archives of Orthopaedic and Trauma SurgeryVol. 146(1)
AO Foundation (CH), Jena University Hospital (DE), University Hospital in Halle (DE)
Universitätsklinikum Jena
Openalex Percentile: Top 32%
Orthopedic Surgery and Rehabilitation
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.