Frequency Band Personalization for Seizure Network Analysis in Multifocal Patients

Stereo-electroencephalography (SEEG) is commonly used for pre-surgical evaluation in patients with multifocal epilepsy undergoing responsive neurostimulation (RNS). Seizure network modeling, a data-driven approach to assist RNS implantation and adjustment, benefits from individualized ictal signatures learned from SEEG data, including repetitive sharp waves, rhythmic discharges, and prominent frequency bands in seizure activities. This is all in pursuit of the earliest possible detection so that the RNS therapy can be delivered as soon as a potential seizure is on the horizon. To improve individualized treatment, this paper proposes a data-driven methodology for personalizing frequency-band selection using a SEEG-based seizure network in patients with multifocal epilepsy. A directed seizure network is first proposed using SEEG data, where network nodes are selected SEEG points, and spectral edges are characterized by a directed transfer function. To further enhance the robustness of network modeling, surrogate data analysis is applied to ensure the significance of network estimation. Then, the density differences between the seizure onset zone and remaining regions are extracted using subgraph density as a heuristic to select the discriminative frequency range with the highest difference as the optimal band. The selection result is further validated using a machine learning classifier for seizure detection. Across ten multifocal patients, our personalized selection achieved an Area-Under score of 0.94 out of 1 in the seizure classification task, outperforming standard bands in distinguishing ictal from pre-ictal states, and exhibiting type-specific spectral patterns with consistency through different frequency-domain network metrics.

Authors

Institutions

Publication Details

Journal
International Journal of Neural Systems
Published
2026-04-06
DOI
https://doi.org/10.1142/s0129065726500371
Primary Topic
EEG and Brain-Computer Interfaces
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Frequency Band Personalization for Seizure Network Analysis in Multifocal Patients

Jay Harvey, Genchang Peng, Mehrdad Nourani, Omar Nofal
International Journal of Neural Systems
EEG and Brain-Computer Interfaces
article

Frequency Band Personalization for Seizure Network Analysis in Multifocal Patients

Jay Harvey, Genchang Peng, Mehrdad Nourani, Omar Nofal
article en

Abstract

Stereo-electroencephalography (SEEG) is commonly used for pre-surgical evaluation in patients with multifocal epilepsy undergoing responsive neurostimulation (RNS). Seizure network modeling, a data-driven approach to assist RNS implantation and adjustment, benefits from individualized ictal signatures learned from SEEG data, including repetitive sharp waves, rhythmic discharges, and prominent frequency bands in seizure activities. This is all in pursuit of the earliest possible detection so that the RNS therapy can be delivered as soon as a potential seizure is on the horizon. To improve individualized treatment, this paper proposes a data-driven methodology for personalizing frequency-band selection using a SEEG-based seizure network in patients with multifocal epilepsy. A directed seizure network is first proposed using SEEG data, where network nodes are selected SEEG points, and spectral edges are characterized by a directed transfer function. To further enhance the robustness of network modeling, surrogate data analysis is applied to ensure the significance of network estimation. Then, the density differences between the seizure onset zone and remaining regions are extracted using subgraph density as a heuristic to select the discriminative frequency range with the highest difference as the optimal band. The selection result is further validated using a machine learning classifier for seizure detection. Across ten multifocal patients, our personalized selection achieved an Area-Under score of 0.94 out of 1 in the seizure classification task, outperforming standard bands in distinguishing ictal from pre-ictal states, and exhibiting type-specific spectral patterns with consistency through different frequency-domain network metrics.

International Journal of Neural Systems
The University of Texas at Dallas (US), The University of Texas Southwestern Medical Center (US)
Reduced inequalities
Openalex Percentile: Top 28%
EEG and Brain-Computer Interfaces
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Frequency Band Personalization for Seizure Network Analysis in Multifocal Patients — Jay Harvey, Genchang Peng, et al. · International Journal of Neural Systems (2026) | TGRS Research Map | TGRS