Influence of Equipment–Structure Interaction on Seismic Response of Seismically Isolated Substation Building

All-indoor substations, where all the electric equipment is set in one building, have been progressively promoted and utilized. Under seismic excitation, both the equipment and the building structures experience dynamic responses, which influence each other. In design practice, floor-mounted electrical equipment is often treated as nonstructural elements and modeled as vertical loads. However, per ASCE 7-23, if such equipment significantly affects the building’s lateral stiffness, it should be modeled with its stiffness and mass considered together as a nonbuilding structure. To investigate the impact of equipment–structure interaction on the dynamic response of the system, a 220[Formula: see text]kV indoor substation was taken as the research subject. A frame-element model of the equipment building and a solid finite element model of the floor-mounted Gas-Insulated Switchgear (GIS) were established. Modal analysis and seismic time-history response analysis were conducted. Three seismic ground motion records (El Centro, Tangshan-NS, and an artificial Lianzhou-1 wave) are used in the time-history analysis, scaled to peak ground accelerations (PGAs) of 0.2g and 0.3g to represent frequent and rare earthquake scenarios, respectively. The results indicate that the interaction between the structure and equipment significantly affects the seismic response of both the structure and the equipment. Under rare earthquake conditions, equipment–structure interaction increases the floor acceleration response of the building, with a maximum increase of 33%. The higher the floor where the equipment is located, the greater the impact of interaction on the structural dynamic response. After seismic isolation for the building, the structural acceleration response and base shear are significantly reduced. However, the equipment–structure interaction still has a notable effect on the seismic response of the structure, resulting in a maximum increase of 12.5% in the story shear.

Authors

Institutions

Publication Details

Journal
Journal of Earthquake and Tsunami
Published
2026-04-06
DOI
https://doi.org/10.1142/s1793431126500089
Primary Topic
Vibration and Dynamic Analysis
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Influence of Equipment–Structure Interaction on Seismic Response of Seismically Isolated Substation Building

Kangming Tian, Yuebing Li, Yuze He, Shuang Xing et al.
Journal of Earthquake and Tsunami
Vibration and Dynamic Analysis
article

Influence of Equipment–Structure Interaction on Seismic Response of Seismically Isolated Substation Building

Kangming Tian, Yuebing Li, Yuze He, Shuang Xing, Zhaoye Ning, Hongpeng Jiang
article en

Abstract

All-indoor substations, where all the electric equipment is set in one building, have been progressively promoted and utilized. Under seismic excitation, both the equipment and the building structures experience dynamic responses, which influence each other. In design practice, floor-mounted electrical equipment is often treated as nonstructural elements and modeled as vertical loads. However, per ASCE 7-23, if such equipment significantly affects the building’s lateral stiffness, it should be modeled with its stiffness and mass considered together as a nonbuilding structure. To investigate the impact of equipment–structure interaction on the dynamic response of the system, a 220[Formula: see text]kV indoor substation was taken as the research subject. A frame-element model of the equipment building and a solid finite element model of the floor-mounted Gas-Insulated Switchgear (GIS) were established. Modal analysis and seismic time-history response analysis were conducted. Three seismic ground motion records (El Centro, Tangshan-NS, and an artificial Lianzhou-1 wave) are used in the time-history analysis, scaled to peak ground accelerations (PGAs) of 0.2g and 0.3g to represent frequent and rare earthquake scenarios, respectively. The results indicate that the interaction between the structure and equipment significantly affects the seismic response of both the structure and the equipment. Under rare earthquake conditions, equipment–structure interaction increases the floor acceleration response of the building, with a maximum increase of 33%. The higher the floor where the equipment is located, the greater the impact of interaction on the structural dynamic response. After seismic isolation for the building, the structural acceleration response and base shear are significantly reduced. However, the equipment–structure interaction still has a notable effect on the seismic response of the structure, resulting in a maximum increase of 12.5% in the story shear.

Journal of Earthquake and Tsunami
Electric Power University (VN), Northeast Electric Power University (CN), Wind Power Engineering (Japan) (JP), China Power Engineering Consulting Group (China) (CN)
Jilin Scientific and Technological Development Program
Sustainable cities and communities
Openalex Percentile: Top 30%
Vibration and Dynamic Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.