Concentration-Adaptive AND-Gate Probe Enables High-Fidelity Imaging of miRNA in Live Cells

ey), which integrates a dual-ATP aptamer with two CHA hairpins. This system enables synchronous response to ATP and microRNA-21 (miR-21), an oncogenic miRNA overexpressed in various malignant tumors. In this target-dependent mechanism, ATP binding triggers initiator release to partially open H1, enabling subsequent miR-21 binding to fully activate the CHA circuit with H2 for strong fluorescence signal amplification. The ATMiR-LOCK system functions as an "AND" logic gate, and it requires the presence of both ATP and miR-21 inputs to generate an output. This dual-input design greatly improves detection specificity and effectively minimizes the background signal. We validated the probe through in vitro experiments, fluorescence imaging in HepG2 liver cancer cells, and tests across multiple cell lines. The results demonstrated high sensitivity, with a picomolar detection limit for miR-21, and an effective response to millimolar levels of cellular ATP in cancer cells, both with excellent specificity and reliability. The ATMiR-LOCK probe represents a promising strategy for developing highly specific diagnostic tools for early tumor detection.

Authors

Institutions

Publication Details

Journal
ACS Sensors
Published
2026-04-06
DOI
https://doi.org/10.1021/acssensors.5c04929
Primary Topic
Advanced biosensing and bioanalysis techniques
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Concentration-Adaptive AND-Gate Probe Enables High-Fidelity Imaging of miRNA in Live Cells

Wei Shen, Lingjie Ma, Dimin Tong, Wen-Xue Zhou et al.
ACS Sensors
Advanced biosensing and bioanalysis techniques
article

Concentration-Adaptive AND-Gate Probe Enables High-Fidelity Imaging of miRNA in Live Cells

Wei Shen, Lingjie Ma, Dimin Tong, Wen-Xue Zhou, Jie Chen, Liang Xu
article en

Abstract

ey), which integrates a dual-ATP aptamer with two CHA hairpins. This system enables synchronous response to ATP and microRNA-21 (miR-21), an oncogenic miRNA overexpressed in various malignant tumors. In this target-dependent mechanism, ATP binding triggers initiator release to partially open H1, enabling subsequent miR-21 binding to fully activate the CHA circuit with H2 for strong fluorescence signal amplification. The ATMiR-LOCK system functions as an "AND" logic gate, and it requires the presence of both ATP and miR-21 inputs to generate an output. This dual-input design greatly improves detection specificity and effectively minimizes the background signal. We validated the probe through in vitro experiments, fluorescence imaging in HepG2 liver cancer cells, and tests across multiple cell lines. The results demonstrated high sensitivity, with a picomolar detection limit for miR-21, and an effective response to millimolar levels of cellular ATP in cancer cells, both with excellent specificity and reliability. The ATMiR-LOCK probe represents a promising strategy for developing highly specific diagnostic tools for early tumor detection.

ACS SensorsVol. 11(4)
Ministry of Education of the People's Republic of China (CN), Wenzhou Medical University (CN), Wuxi Third People's Hospital (CN), Laboratoire de Génétique Médicale (FR)
Health Commission of Zhejiang Province, Science and Technology Plan Project of Wenzhou, China
Openalex Percentile: Top 23%
Advanced biosensing and bioanalysis techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.