Wall heat transfer and flow field configuration of shock wave–turbulent boundary layer interactions on cryogenically cooled wall

In this study, we experimentally investigated the wall heat transfer and flow field configuration of incident-reflected shock wave–turbulent boundary layer interactions on a cooled wall in supersonic flow. Wind tunnel experiments were conducted at a Mach number of 2.0 and a total temperature of 289 K. To create a cooled-wall state, the wind tunnel wall was cooled to a cryogenic temperature using liquid nitrogen at 77.4 K. In addition to conventional measurements, such as the schlieren visualization method and pressure measurements, cryogenic temperature-sensitive paint was employed to clarify the relationship between the flow field configuration and wall heat flux on a cryogenically cooled wall. The wall surface temperature of the cryogenically cooled wall was 95 K, corresponding to a wall-to-recovery temperature ratio of 0.34. The oil flow image and wall surface temperature distribution indicated a quasi-two-dimensional flow at the center of the wind tunnel. The schlieren images and wall pressure distributions showed that the separation point under the cooled-wall condition shifted downstream compared with that under the uncooled-wall condition. Based on the temperature distribution obtained from the cooled-wall experiments, the wall heat flux at the separation point reduced due to the outward flow from the wall. The peak wall pressure ratio and wall heat flux ratio normalized by their upstream values exhibited trends consistent with previously reported data under the cooled-wall condition. These results suggest that the cryogenic temperature-sensitive paint is a powerful tool for investigating the effects of wall temperature on the shock wave–turbulent boundary layer interactions on cryogenically cooled walls.

Authors

Institutions

Publication Details

Journal
Physics of Fluids
Published
2026-04-01
DOI
https://doi.org/10.1063/5.0321514
Primary Topic
Computational Fluid Dynamics and Aerodynamics
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Wall heat transfer and flow field configuration of shock wave–turbulent boundary layer interactions on cryogenically cooled wall

Yasuhiro Egami, Azumi Miyazaki, Yuma Miki, Leo Ando et al.
Physics of Fluids
Computational Fluid Dynamics and Aerodynamics
article

Wall heat transfer and flow field configuration of shock wave–turbulent boundary layer interactions on cryogenically cooled wall

Yasuhiro Egami, Azumi Miyazaki, Yuma Miki, Leo Ando, Kiyoshi Kinefuchi
article en

Abstract

In this study, we experimentally investigated the wall heat transfer and flow field configuration of incident-reflected shock wave–turbulent boundary layer interactions on a cooled wall in supersonic flow. Wind tunnel experiments were conducted at a Mach number of 2.0 and a total temperature of 289 K. To create a cooled-wall state, the wind tunnel wall was cooled to a cryogenic temperature using liquid nitrogen at 77.4 K. In addition to conventional measurements, such as the schlieren visualization method and pressure measurements, cryogenic temperature-sensitive paint was employed to clarify the relationship between the flow field configuration and wall heat flux on a cryogenically cooled wall. The wall surface temperature of the cryogenically cooled wall was 95 K, corresponding to a wall-to-recovery temperature ratio of 0.34. The oil flow image and wall surface temperature distribution indicated a quasi-two-dimensional flow at the center of the wind tunnel. The schlieren images and wall pressure distributions showed that the separation point under the cooled-wall condition shifted downstream compared with that under the uncooled-wall condition. Based on the temperature distribution obtained from the cooled-wall experiments, the wall heat flux at the separation point reduced due to the outward flow from the wall. The peak wall pressure ratio and wall heat flux ratio normalized by their upstream values exhibited trends consistent with previously reported data under the cooled-wall condition. These results suggest that the cryogenic temperature-sensitive paint is a powerful tool for investigating the effects of wall temperature on the shock wave–turbulent boundary layer interactions on cryogenically cooled walls.

Physics of FluidsVol. 38(4)
Aichi Institute of Technology (JP), Nagoya University (JP)
Support for Pioneering Research Initiated by the Next Generation, Japan Society for the Promotion of Science
Openalex Percentile: Top 20%
Computational Fluid Dynamics and Aerodynamics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.