Efficient separation of Fenton ferric flocs by optimized-design hydrocyclone

• A hydrocyclone for Fenton floc was optimized via single factor, RSM, and NSGA-II. • Wide-angle hydrocyclone surpassed mini-hydrocyclone and Rietema hydrocyclone. • Four key structural parameters were identified. • Optimized hydrocyclone achieved 96.09% SS removal and 5.62 concentration factor. • Optimized hydrocyclone cuts footprint and costs by 41∼89% vs sedimentation. Efficient separation of ferric flocs is a critical challenge in iron-based homogeneous Fenton treatment due to the poor settleability and shear sensitivity of the generated flocs. In this study, a hydrocyclone-based separation strategy was systematically optimized to provide an intensified alternative to conventional gravity-driven sedimentation. Among the investigated hydrocyclone outlines, a wide-angle design exhibited superior separation performance and was further optimized by integrating single-factor experiments, response surface modeling, and NSGA-II optimization. The optimized hydrocyclone achieved a suspended solids removal efficiency of 96.09% and a concentration factor of 5.62. Mechanistic analysis based on flocs morphology revealed that coordinated structural modifications, including elimination of vortex finder insertion, enlargement of the cylindrical diameter, extension of the cylindrical length, and increase of underflow pipe diameters, effectively alleviated shear-induced flocs breakage and enhanced separation efficiency. The optimized hydrocyclone demonstrated robust performance within the recommend operating conditions, which are a feed flow rate below 15 L/h, a split ratio of 14%, and a FeSO 4 concentration below 7 mM. The effectiveness of the optimized hydrocyclone was successfully validated using real refractory industrial wastewaters without inducing organic matter release. Economic evaluation showed that, compared with typical gravity-driven sedimentation, the optimized hydrocyclone reduced footprint by 50%∼88.6%, capital cost by 51.28%∼80.65%, and operation cost by 40.99%∼83.11%. Overall, this study presents a compact, cost-effective, and environmentally sustainable solution for Fenton ferric floc separation, with strong potential for practical engineering application.

Authors

Institutions

Publication Details

Journal
Journal of Hazardous Materials Advances
Published
2026-04-06
DOI
https://doi.org/10.1016/j.hazadv.2026.101152
Primary Topic
Coagulation and Flocculation Studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Efficient separation of Fenton ferric flocs by optimized-design hydrocyclone

Zhe Tian, Yunxing Dong, Yingxin Gao, Fengjuan Ma et al.
Journal of Hazardous Materials Advances
Coagulation and Flocculation Studies
article

Efficient separation of Fenton ferric flocs by optimized-design hydrocyclone

Zhe Tian, Yunxing Dong, Yingxin Gao, Fengjuan Ma, Min Yang, Yi Liu
article en

Abstract

• A hydrocyclone for Fenton floc was optimized via single factor, RSM, and NSGA-II. • Wide-angle hydrocyclone surpassed mini-hydrocyclone and Rietema hydrocyclone. • Four key structural parameters were identified. • Optimized hydrocyclone achieved 96.09% SS removal and 5.62 concentration factor. • Optimized hydrocyclone cuts footprint and costs by 41∼89% vs sedimentation. Efficient separation of ferric flocs is a critical challenge in iron-based homogeneous Fenton treatment due to the poor settleability and shear sensitivity of the generated flocs. In this study, a hydrocyclone-based separation strategy was systematically optimized to provide an intensified alternative to conventional gravity-driven sedimentation. Among the investigated hydrocyclone outlines, a wide-angle design exhibited superior separation performance and was further optimized by integrating single-factor experiments, response surface modeling, and NSGA-II optimization. The optimized hydrocyclone achieved a suspended solids removal efficiency of 96.09% and a concentration factor of 5.62. Mechanistic analysis based on flocs morphology revealed that coordinated structural modifications, including elimination of vortex finder insertion, enlargement of the cylindrical diameter, extension of the cylindrical length, and increase of underflow pipe diameters, effectively alleviated shear-induced flocs breakage and enhanced separation efficiency. The optimized hydrocyclone demonstrated robust performance within the recommend operating conditions, which are a feed flow rate below 15 L/h, a split ratio of 14%, and a FeSO 4 concentration below 7 mM. The effectiveness of the optimized hydrocyclone was successfully validated using real refractory industrial wastewaters without inducing organic matter release. Economic evaluation showed that, compared with typical gravity-driven sedimentation, the optimized hydrocyclone reduced footprint by 50%∼88.6%, capital cost by 51.28%∼80.65%, and operation cost by 40.99%∼83.11%. Overall, this study presents a compact, cost-effective, and environmentally sustainable solution for Fenton ferric floc separation, with strong potential for practical engineering application.

Journal of Hazardous Materials AdvancesVol. 22
East China University of Science and Technology (CN), Chinese Academy of Sciences (CN), Research Center for Eco-Environmental Sciences (CN), University of Chinese Academy of Sciences (CN)
Openalex Percentile: Top 11%
Coagulation and Flocculation Studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.