Monte Carlo Assessment of Accuracy for Mean Kärger Model Water Exchange Rate Estimates From Diffusional Kurtosis Time Dependence

Intercompartmental water exchange in brain and other biological tissue can be probed in vivo with diffusion MRI (dMRI). We assess the accuracy of a recently proposed method for estimating a mean exchange rate by performing Monte Carlo simulations of random walkers through a packing of permeable, randomly placed, parallel cylinders to model water exchange within axonal fiber bundles. The diffusivity and kurtosis of the full system are calculated for a broad range of diffusion times and model parameters. The mean exchange rate is estimated from the logarithmic derivative of the kurtosis with respect to the diffusion time and compared with the exchange rate predicted by the Kärger model (KM), which is exact in certain limits. The mean exchange rate is also compared with the reciprocal exchange time obtained by conventional fitting of the kurtosis time dependence to a two-compartment KM, with a high correlation being found between the two quantities. The estimates from the logarithmic derivative are in good agreement with the KM predictions when the exchange time is long in comparison to the compartment traversal times, which corresponds to barrier-limited exchange. Compared to the standard procedure of fitting the kurtosis to the KM over a broad range of diffusion times, using the logarithmic derivative reduces the data acquisition burden by only requiring a narrow range of times and increases generality in that number of compartments need not be specified. This method may be useful for estimating the mean exchange rate from the kurtosis time dependence measured with dMRI.

Authors

Institutions

Publication Details

Journal
NMR in Biomedicine
Published
2026-04-06
DOI
https://doi.org/10.1002/nbm.70281
Primary Topic
Advanced Neuroimaging Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Monte Carlo Assessment of Accuracy for Mean Kärger Model Water Exchange Rate Estimates From Diffusional Kurtosis Time Dependence

Ricardo Coronado‐Leija, Jens H. Jensen, Els Fieremans
NMR in Biomedicine
Advanced Neuroimaging Techniques and Applications
article

Monte Carlo Assessment of Accuracy for Mean Kärger Model Water Exchange Rate Estimates From Diffusional Kurtosis Time Dependence

Ricardo Coronado‐Leija, Jens H. Jensen, Els Fieremans
article en

Abstract

Intercompartmental water exchange in brain and other biological tissue can be probed in vivo with diffusion MRI (dMRI). We assess the accuracy of a recently proposed method for estimating a mean exchange rate by performing Monte Carlo simulations of random walkers through a packing of permeable, randomly placed, parallel cylinders to model water exchange within axonal fiber bundles. The diffusivity and kurtosis of the full system are calculated for a broad range of diffusion times and model parameters. The mean exchange rate is estimated from the logarithmic derivative of the kurtosis with respect to the diffusion time and compared with the exchange rate predicted by the Kärger model (KM), which is exact in certain limits. The mean exchange rate is also compared with the reciprocal exchange time obtained by conventional fitting of the kurtosis time dependence to a two-compartment KM, with a high correlation being found between the two quantities. The estimates from the logarithmic derivative are in good agreement with the KM predictions when the exchange time is long in comparison to the compartment traversal times, which corresponds to barrier-limited exchange. Compared to the standard procedure of fitting the kurtosis to the KM over a broad range of diffusion times, using the logarithmic derivative reduces the data acquisition burden by only requiring a narrow range of times and increases generality in that number of compartments need not be specified. This method may be useful for estimating the mean exchange rate from the kurtosis time dependence measured with dMRI.

NMR in BiomedicineVol. 39(5)
Medical University of South Carolina (US), New York University (US)
National Institutes of Health
Clean water and sanitation
Openalex Percentile: Top 19%
Advanced Neuroimaging Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.