Evaluation of precision and method comparison of the Mindray BC-5000 Vet hematology analyzer in the cynomolgus macaque

= 0.6-0.7). Good agreement was found in the Bland-Altman analysis of Hct, and concentrations of RBCs, WBCs, neutrophils, and lymphocytes, with narrow limits of agreement. Monocyte concentrations were in moderate agreement given a small positive proportional bias; Hb, MCV, MCH, mean corpuscular hemoglobin concentration, eosinophils, and basophils had wider limits of agreement and proportional bias, indicating underestimation by the analyzer. Bland-Altman findings were consistent with regression analyses. Based on combined precision and method comparisons, the BC-5000 Vet provides reliable performance for routine CBC analysis in healthy cynomolgus macaques.

Authors

Institutions

Publication Details

Journal
Journal of Veterinary Diagnostic Investigation
Published
2026-04-06
DOI
https://doi.org/10.1177/10406387261438155
Primary Topic
Clinical Laboratory Practices and Quality Control
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Evaluation of precision and method comparison of the Mindray BC-5000 Vet hematology analyzer in the cynomolgus macaque

Piya Sereerak, Kanitta Srinoun, Sorawat Thongsahuan, Domechai Kaewnoi et al.
Journal of Veterinary Diagnostic Investigation
Clinical Laboratory Practices and Quality Control
article

Evaluation of precision and method comparison of the Mindray BC-5000 Vet hematology analyzer in the cynomolgus macaque

Piya Sereerak, Kanitta Srinoun, Sorawat Thongsahuan, Domechai Kaewnoi, Salintorn Thongsahuan, Amin Chenae
article en

Abstract

= 0.6-0.7). Good agreement was found in the Bland-Altman analysis of Hct, and concentrations of RBCs, WBCs, neutrophils, and lymphocytes, with narrow limits of agreement. Monocyte concentrations were in moderate agreement given a small positive proportional bias; Hb, MCV, MCH, mean corpuscular hemoglobin concentration, eosinophils, and basophils had wider limits of agreement and proportional bias, indicating underestimation by the analyzer. Bland-Altman findings were consistent with regression analyses. Based on combined precision and method comparisons, the BC-5000 Vet provides reliable performance for routine CBC analysis in healthy cynomolgus macaques.

Journal of Veterinary Diagnostic Investigation
Prince of Songkla University (TH), Department of National Parks Wildlife and Plant Conservation (TH)
Prince of Songkla University
Openalex Percentile: Top 22%
Clinical Laboratory Practices and Quality Control
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.