Finite‐Element Comparison of a Proximal Femoral Laterally Bionic Intramedullary Nail ( <scp>PFLBN</scp> ) Versus <scp>PFNA</scp> and <scp>PFBN</scp> for <scp>AO</scp> / <scp>OTA</scp> 31‐ <scp>A3</scp> .1 Intertrochanteric Fractures

OBJECTIVE: The proximal femoral laterally bionic intramedullary nail (PFLBN) is a novel cephalomedullary fixation system incorporating an additional lateral wall screw. This study aimed to compare the stress distribution and displacement characteristics of PFLBN with those of proximal femoral nail antirotation (PFNA) and proximal femoral bionic nail (PFBN) in AO/OTA 31-A3.1 intertrochanteric fractures using finite element analysis. METHOD: Finite element models of an AO/OTA 31-A3.1 intertrochanteric femoral fracture were constructed based on computed tomography data from a healthy adult femur. Three fixation constructs (PFNA, PFBN, and PFLBN) were simulated under axial loading representing single-leg stance equivalent to three times body weight (2100 N). Von Mises stress distribution and displacement patterns of the femur and implants were evaluated. RESULT: In all models, peak implant stress was concentrated at the junction between the main nail and the cephalocervical component. Compared with PFNA, the PFLBN model demonstrated a 17.2% reduction in peak implant stress and a 23.2% reduction in peak femoral stress. Maximum femoral and implant displacements in the PFLBN model were reduced by 19.5% and 19.2%, respectively. Notably, the PFLBN exhibited the highest construct stiffness and effectively mitigated stress concentration on the medial femoral cortex through the load-redistribution mechanism of the lateral wall screw. While the PFBN showed improved metrics over the PFNA, the PFLBN provided superior mechanical stability specifically for the simulated lateral wall deficiency. CONCLUSION: Under axial single-leg stance loading, PFLBN exhibited lower peak stresses and smaller displacements than PFNA and PFBN in this finite element model of AO/OTA 31-A3.1 fractures. These computational findings describe differences in stress redistribution and construct behavior and warrant further experimental and clinical validation.

Authors

Institutions

Publication Details

Journal
Orthopaedic Surgery
Published
2026-04-06
DOI
https://doi.org/10.1111/os.70274
Primary Topic
Hip and Femur Fractures
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Finite‐Element Comparison of a Proximal Femoral Laterally Bionic Intramedullary Nail ( PFLBN ) Versus PFNA and PFBN for AO / OTA 31‐ A3 .1 Intertrochanteric Fractures

Chen Xiong, Lijia Zhang, H X Fu, Yichong Zhang et al.
Orthopaedic Surgery
Hip and Femur Fractures
article

Finite‐Element Comparison of a Proximal Femoral Laterally Bionic Intramedullary Nail ( PFLBN ) Versus PFNA and PFBN for AO / OTA 31‐ A3 .1 Intertrochanteric Fractures

Chen Xiong, Lijia Zhang, H X Fu, Yichong Zhang, Xiaofeng Chen, Zhentao Ding, Xiaomeng Zhang, Yanhua Wang
article en

Abstract

OBJECTIVE: The proximal femoral laterally bionic intramedullary nail (PFLBN) is a novel cephalomedullary fixation system incorporating an additional lateral wall screw. This study aimed to compare the stress distribution and displacement characteristics of PFLBN with those of proximal femoral nail antirotation (PFNA) and proximal femoral bionic nail (PFBN) in AO/OTA 31-A3.1 intertrochanteric fractures using finite element analysis. METHOD: Finite element models of an AO/OTA 31-A3.1 intertrochanteric femoral fracture were constructed based on computed tomography data from a healthy adult femur. Three fixation constructs (PFNA, PFBN, and PFLBN) were simulated under axial loading representing single-leg stance equivalent to three times body weight (2100 N). Von Mises stress distribution and displacement patterns of the femur and implants were evaluated. RESULT: In all models, peak implant stress was concentrated at the junction between the main nail and the cephalocervical component. Compared with PFNA, the PFLBN model demonstrated a 17.2% reduction in peak implant stress and a 23.2% reduction in peak femoral stress. Maximum femoral and implant displacements in the PFLBN model were reduced by 19.5% and 19.2%, respectively. Notably, the PFLBN exhibited the highest construct stiffness and effectively mitigated stress concentration on the medial femoral cortex through the load-redistribution mechanism of the lateral wall screw. While the PFBN showed improved metrics over the PFNA, the PFLBN provided superior mechanical stability specifically for the simulated lateral wall deficiency. CONCLUSION: Under axial single-leg stance loading, PFLBN exhibited lower peak stresses and smaller displacements than PFNA and PFBN in this finite element model of AO/OTA 31-A3.1 fractures. These computational findings describe differences in stress redistribution and construct behavior and warrant further experimental and clinical validation.

Orthopaedic SurgeryVol. 18(5)
Chinese Academy of Medical Sciences & Peking Union Medical College (CN), Peking University (CN), Peking Union Medical College Hospital (CN), Peking University People's Hospital (CN), First Affiliated Hospital Zhejiang University (CN)
National Natural Science Foundation of China, Beijing Municipal Natural Science Foundation
Openalex Percentile: Top 35%
Hip and Femur Fractures
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.