XACT‐guided interventional procedures: A feasibility study

BACKGROUND: X-ray Induced Acoustic Computed Tomography (XACT) is an emerging imaging technique that provides 3D volumetric images from a single projection by detecting X-ray-induced acoustic (XA) waves with ultrasound (US) transducers. Unlike MRI or CT, XACT enables real-time 3D imaging without long acquisition times, 2D limitations, or motion artifacts from mechanical rotation. Furthermore, when integrated with conventional pulse-echo US through time-sequenced operation, XACT provides complementary soft-tissue contrast, establishing it as a promising platform for dynamic interventional radiology (IR) guidance. PURPOSE: This study aims to evaluate the feasibility of XACT as a novel imaging tool for IR, specifically for guiding needle placement and monitoring contrast agent dynamics. METHODS: We developed a 3D XACT imaging system equipped with a 256-element 2D matrix array and a portable X-ray tube to visualize needle insertion and contrast agent dynamics. To capture both needle position and soft tissue anatomy, we integrated a dual-modality system combining XACT with pulse-echo US using a 128-element linear US array. Experiments were conducted on both tissue-mimic phantoms and soft tissue samples. GPU-accelerated algorithm has been developed for 3D XACT image reconstruction. RESULTS: The results demonstrate the 3D capabilities of XACT imaging for interventional procedures, including monitoring of needle placement and tracking of contrast agent dynamics. The imaging speed reached up to 3∼4 s per frame, constrained by the repetition rate of the X-ray source and signal to noise ratio. The dual-modality approach provided clear visualization of the needle's position and the surrounding soft tissue structures, achieving imaging resolution around 2 mm. CONCLUSIONS: This study demonstrates that XACT imaging is feasible to be used for IR. Its 3D imaging capability with faster imaging speed would be an alternative to cone beam CT and its capability to combine US imaging will provide richer information for soft tissue.

Authors

Institutions

Publication Details

Journal
Medical Physics
Published
2026-04-01
DOI
https://doi.org/10.1002/mp.70401
Primary Topic
Advanced Radiotherapy Techniques
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

XACT‐guided interventional procedures: A feasibility study

‪Zhehui Wang, Nadine Abi‐Jaoudeh, Prabodh Kumar Pandey, Leshan Sun et al.
Medical Physics
Advanced Radiotherapy Techniques
article

XACT‐guided interventional procedures: A feasibility study

‪Zhehui Wang, Nadine Abi‐Jaoudeh, Prabodh Kumar Pandey, Leshan Sun, Yuchen Yan, Yifei Xu, Shawn (Liangzhong) Xiang
article en

Abstract

BACKGROUND: X-ray Induced Acoustic Computed Tomography (XACT) is an emerging imaging technique that provides 3D volumetric images from a single projection by detecting X-ray-induced acoustic (XA) waves with ultrasound (US) transducers. Unlike MRI or CT, XACT enables real-time 3D imaging without long acquisition times, 2D limitations, or motion artifacts from mechanical rotation. Furthermore, when integrated with conventional pulse-echo US through time-sequenced operation, XACT provides complementary soft-tissue contrast, establishing it as a promising platform for dynamic interventional radiology (IR) guidance. PURPOSE: This study aims to evaluate the feasibility of XACT as a novel imaging tool for IR, specifically for guiding needle placement and monitoring contrast agent dynamics. METHODS: We developed a 3D XACT imaging system equipped with a 256-element 2D matrix array and a portable X-ray tube to visualize needle insertion and contrast agent dynamics. To capture both needle position and soft tissue anatomy, we integrated a dual-modality system combining XACT with pulse-echo US using a 128-element linear US array. Experiments were conducted on both tissue-mimic phantoms and soft tissue samples. GPU-accelerated algorithm has been developed for 3D XACT image reconstruction. RESULTS: The results demonstrate the 3D capabilities of XACT imaging for interventional procedures, including monitoring of needle placement and tracking of contrast agent dynamics. The imaging speed reached up to 3∼4 s per frame, constrained by the repetition rate of the X-ray source and signal to noise ratio. The dual-modality approach provided clear visualization of the needle's position and the surrounding soft tissue structures, achieving imaging resolution around 2 mm. CONCLUSIONS: This study demonstrates that XACT imaging is feasible to be used for IR. Its 3D imaging capability with faster imaging speed would be an alternative to cone beam CT and its capability to combine US imaging will provide richer information for soft tissue.

Medical PhysicsVol. 53(4)
Los Alamos National Laboratory (US), University of California, Irvine (US), WinnMed (US), Beckman Laser Institute and Medical Clinic (US), Irvine University (US), Mayo Clinic in Florida (US)
National Institutes of Health
Openalex Percentile: Top 29%
Advanced Radiotherapy Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.