LCL-833 Master Resurrection Edition: Full Data Companion

LCL 832 is a [[832, 2, d ≥ 4]] (where d ≤ 187) genus 5 generalized bicycle CSS code. The restricted files contain the Hx and Hz parity matrices, which are CSS orthogonal with a rank of 415/415, a row weight of 8, and a column weight of 4. These files also include the v14 analysis pipeline and live hardware calibration data collected on the ibm_kingston Heron r3 processor. The threshold proof under phenomenological noise indicates a p_th of approximately 0.02, with a 95% CI of [0.01, 0.02]. Furthermore, operator fidelity calibration on live hardware is considered PARTIAL. While the canonical α_op of 0.7924 falls inside the 95% CI of the injection closure path, the combined CI width is 0.089. This width does not satisfy the author's STRONG criterion, which requires a width of less than 0.05. Finally, a full audit of refuted overclaims is included in the bundle, with access granted upon request under an NDA.

Authors

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2026-04-06
DOI
https://doi.org/10.5281/zenodo.19437054
Primary Topic
Quantum Computing Algorithms and Architecture
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

LCL-833 Master Resurrection Edition: Full Data Companion

Guillaume Lessard
Zenodo (CERN European Organization for Nuclear Research)
Quantum Computing Algorithms and Architecture
article

LCL-833 Master Resurrection Edition: Full Data Companion

Guillaume Lessard
article en

Abstract

LCL 832 is a [[832, 2, d ≥ 4]] (where d ≤ 187) genus 5 generalized bicycle CSS code. The restricted files contain the Hx and Hz parity matrices, which are CSS orthogonal with a rank of 415/415, a row weight of 8, and a column weight of 4. These files also include the v14 analysis pipeline and live hardware calibration data collected on the ibm_kingston Heron r3 processor. The threshold proof under phenomenological noise indicates a p_th of approximately 0.02, with a 95% CI of [0.01, 0.02]. Furthermore, operator fidelity calibration on live hardware is considered PARTIAL. While the canonical α_op of 0.7924 falls inside the 95% CI of the injection closure path, the combined CI width is 0.089. This width does not satisfy the author's STRONG criterion, which requires a width of less than 0.05. Finally, a full audit of refuted overclaims is included in the bundle, with access granted upon request under an NDA.

Zenodo (CERN European Organization for Nuclear Research)
Peace, Justice and strong institutions
Openalex Percentile: Top 22%
Quantum Computing Algorithms and Architecture
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.